![AT&T 4 ESS Скачать руководство пользователя страница 167](http://html1.mh-extra.com/html/atandt/4-ess/4-ess_manual_2994836167.webp)
ANALYZE FAILING TEST DATA TO DETERMINE TEST FUNCTION
TEST MISMATCH SUPPLEMENTARY DATA
PURB*PUAB — PUWB(35-24)*PUWB(23-0)*ADR*UDS-TLP
28630 02000000 75777757 00000000 01000240 00000053 04200002
five raw data printout words that follow mismatch
test to determine what was occurring prior to test
1. Read several
DIAL
statements just before failing
2. Read failing test
DIAL
statement and any comments
3. Note
"
asterisk data
"
that follows failing test
4. Note relationship of asterisk line data to first
16-12 = SP number, 11-10 = Matrix, 09-04 = Row, 03-00 = Column
NOTE: Section 234-180-020 contains a description
third data word breaks down as follows: 23-17 = Don’t care,
NOTE: For scan point, SD point, and SP point addresses,
5. In TABLE A, Page 2, locate failing
DIAL
statement
data contained in second and third raw data words
and use description column to determine meaning of
with respect to second and third data words
6. Use TABLE B, Page 3, to obtain additional information
number in listing
following mismatch data
failing
of
DIAL
statements
Figure 1 — Example of Raw Data Printout Relationship to Asterisk Line at Failing Test
data [Figure 1]
502
DLP
PAGE 1 of 3
234-151-013
DEC 1995
Issue 8