Converter
replaced
If a +5v converter
accidentally dislodges in
When replacing a +5v
converter at location
19-31 or 19-42, always
prevent the op5v
converter from dislodging
by holding it in with one
hand while removing or
inserting a +5v converter
with the other hand.
AND
AND
[6] Clean and lubricate converter terminals and
ENABLE/DISABLE
switch to
DISABLE
ROS
Power
removed
NOTE 1
Fuses should always be replaced as
quickly as possible to prevent oscillator
from cooling down. If converter LED
lights or blown fuse remains removed for
longer than 5 minutes, allow 24 hours
before returning oscillator to service
an in-service chain when
replacing a +5v
AND
[10] Depress and hold
TEST
Converter LED lights
[8] Replace any removed fuse and depress and
ENABLE/DISABLE
switch to
ENABLE
PWR OFF
lamp
goes off
hold
ON
pushbutton for 2 seconds
NCSU, position each oscillator
Converter LED goes off
REPLACE CONVERTER
seating of replacement converter
switch for 2 seconds
[5] Remove converter to be replaced
connector per approved procedures
[11] Depress
ON
pushbutton
[2] If circuit pack to be replaced is
in NCSU, position each oscillator
[9] If replaced converter is in
[7] Insert and ensure proper
[4] See CAUTION 1 and NOTE 1. If converter is
listed in TABLE B, Page 2, remove fuse
converter, DO NOT touch
the dislodged converter.
Fault recovery software
After the chain being
worked on is restored to
service, proceed with
correctly restoring the
dislodged converter,
associated oscillator,
and associated chain by
repeating from Step 1 of
this procedure and
proceeding to Step 2 of
NTP-009.
[1] Rotate
ROS/OFF
switch for
applicable converter
[3] Depress
ROS/OFF
switch
OFF NORM
and
OS
lamps light
PWR OFF
lamp lights
CAUTION 1
recovers that chain.
DLP
PAGE 1 of 2
234-151-013
509
Issue 8
DEC 1995