![ATAGO Twilight AT-CM800a Скачать руководство пользователя страница 7](http://html.mh-extra.com/html/atago/twilight-at-cm800a/twilight-at-cm800a_instruction-manual_2995849007.webp)
-4-
Handling of this instrument (Continued)
CAUTION
◇DO NOT measure any sample that can damage the
prism or the sample inlet unit.
◇Sample temperature should be kept between 5℃
and 100℃ when the power is turned on.
◇Cleaning liquids up to 150℃ can be used for CIP or
SIP. The cleaning liquid can be used safely for 30
minutes at one time. The momentary difference
between the sample liquid temperature and the
cleaning liquid temperature must be no more than
80℃.
When using cleaning liquids at temperatures over
150℃, the power source (DC24V) must be turned
off. If the AD-32 (AD-33 or AD-34) is used, unplug
from the outlet before cleaning.
◇The lower limit value of wetted parts temperature is
-30℃.
◇ If the sample could possibly stain the prism,
immediately clean the prism according to the
procedure described on page 32 "15. Cleaning the
Prism".
◇The CM-800α power (DC24V) should be turned off
when it is not to be used for a long period of time. If
the AD adapter AD-32, AD-33 or AD-34 (optional) is
used, disconnect the power cable plug from the AC
100-240V outlet.
◇When transporting the instrument, pack it in the
original box.
◇When transporting by aircraft, disconnect the power
(DC24V) cable or the DC output cable of the AC
adapter AD-32, AD-33 or AD-34 (optional) from the
power input terminal of the CM-800α.
◇Carefully read this instruction manual and fully understand the function and operation of each part of the
instrument before use.
◇Check that each part of the instrument operates normally before use.
◇Perform the necessary inspections and reference adjustments according to the instruction manual.
◇The manufacturer shall not be held responsible for any damage that results from using the instrument for other
than its intended purposes (measurement of Brix(%), sugar content, liquid concentration).
◇The manufacturer shall not be held responsible if the use of the instrument has an undesired effect on the
measured materials.
◇The prism in contact with the sample is a consumable item.