GB 28
Connection
•
The hob is connected according to diagram 230V 2Nac (see the
diagram at the bottom of the appliance). If another connection
is required, let a registered electrical service technician make the
connection.
If you want to make a fixed connection, make sure that a multi-
•
polar switch with a contact separation of at least 3 mm is fitted in
the supply line.
The power cord is a type Y. This means that the power cord may
•
only be replaced by the manufacturer, the manufacturers service
organisation or equivalently qualified persons, in order to avoid
dangerous situations.
Common connection:
3 phase and 1 zero connection (3 1N, 400 V ~ / 50 Hz):
•
The voltage between the phases and the zeros is 230 V ~.
º
The voltage between the two phases is 400 V ~.
Fit a connecting bridge between connecting points 4-5.
Phase 3 carries no load. The groups must have fuses of at least
16 A (3x). The core diameter of the connecting cable must be
at least 2.5 mm2.
•
2 phase and 2 zero connection (2 2N, 230 V ~ / 50 Hz):
The voltage between the phases and the zeros is 230 V ~.
º
The group must have fuses of at least 16 A (2x). The core
diameter of the connecting cable must be at least 2.5 mm2.
The bridges on the connecting block can be used to create the
required connections, as indicated in these illustrations.
Fix the cable with a pull relief and close the cover.
Connecting point, wall-mounting socket and plug must be accessible
at all times.
Electrical connection
INSTALLATION INSTRUCTIONS