Owner Installation Instructions
DCB-05V2 Gate Controller
23
Parameter
Min
Max
Default
Menu
Section
Menu 8 - Diagnostics
TEST INPUTS - Controls input display status
Inactive
8.1
Appendix D
TEST TRANSMITTERS (TX’ERS)
8.2
Appendix D
DISPLAY HISTORY
8.3
Appendix D
MEMORY USAGE
8.4
Appendix D
SERVICE COUNTER
60,000
8.5
Appendix D
EVENT COUNTER
8.6
Appendix D
Menu 9 - Memory Tools
CLR CONTROL
9.1
Appendix E
CLR TRANSMITTERS (TX’ERS)
9.2
Appendix E
Menu 10 - Setup Travel
SETUP LIMITS
10.1
8.1
TIME TRAVELED
10.2
Appendix H
REPROFILE TRAVEL
10.3
9.5
SET PEDESTRIAN
10.4
12.1
The standard operation of the opener can be altered by editing various parameters. This section describes the parameters
and the effect they have. Use the VIEWING AND EDITING PARAMETER PROCEDURE (Appendix B) to make changes.
C - Control Board Adjustments
Appendix
Menu 6. Motor settings
Motor speed
The motor settings adjust various aspects of the gate travel.
When a single gate installation is used the SYNC DELAY
TIMES and M2 settings are ignored. The default value for
the CLOSE SYNC DELAY time is automatically calculated
for LIMIT SWITCH/AMP TRAVEL installations. The value
calculated is selected so that the delay between M2 and
M1 reaching the close position is equal to the OPEN SYNC
DELAY TIME. The MAX OVERRUN TIME is set to 0 for
TIMED TRAVEL installations.
Menu 7. Operating Modes
Menu 7.1 First (SB1) Safety Beam Type
Select what type of Safety Beam (2 WIRE or 3 WIRE). 2
WIRE is default.
Menu 7.2 Second (SB2) Safety Beam Type
Select what type of Safety Beam (2 WIRE or 3 WIRE). 2
WIRE is default.
Menu 7.3 First (SB1) Safety Beam Response Mode
The Safety Beams input can be configured to respond in
one of eight modes.
i. Not Used
ii. Close to Reverse
In this mode, the Safety Beam
input has no effect when opening but will cause the
gate to
reverse if activated when closing.
iii. Close to Stop
In this mode, the Safety Beam input
has no effect when opening but will stop the gate
when
closing.
iv. Open and Close to Stop
In this mode, all cycles are
prevented from being completed or initiated when
the
Safety Beam input is active
.
v. Open input
In this mode, open cycle is initiated
when the Safety Beam is activated.
vi. Swipe input
In this mode, open cycle is initiated
when the Safety Beam is activated.
vii. Close input
In this mode, close cycle is initiated
when the Safety Beam is activated.
viii. Ped input
In this mode, ped cycle is initiated when
the Safety Beam is activated.
ix. Disabled
In this mode, Safety Beam is disabled.
Menu 7.4 Second Safety Beam (SB2) Response Mode
Same as above menu 7.3
Menu 7.5 PED Input Function
If GPI or Fire Input is selected as PED then these inputs
can be configured to a SWIPE type input for pedestrian
access. This provides full functionality with the Safety Beam
Triggered Pedestrian Auto-Close function.
Menu 7.6 Open (Opn) Input
(Activated by OPN terminal with N/O switch, by transmitter
button with OPN function assigned or by console’s UP
button) Activating the OPN input will cause the gate to
open. Holding the input will prevent closing.
Menu 7.7 Stop (STP) Input
(Activated by STP terminal with N/O switch, by transmitter
button with STP function assigned or by console’s EXIT
button) Activating the STP input while the gate is moving
will cause the gate to be stopped. If the STP terminal is
held it will prevent the gate from being moved.
Menu 7.8 AUX Input
Is Default to Light, however can be changed to Motor
Engaged.
Menu 7.9 Vacation Mode
Vacation mode can be turned on or off using this parameter.
DCB-05V2 supports a Vacation mode where remote control
access is disabled. The mode is activated by pressing a
transmitter button with the VAC function assigned until the
console displays that vacation mode is enabled (approx.
5 seconds). When activated any transmitter button which
is assigned VAC will be ignored. To turn the Vacation
mode off, simple press a transmitter button with the
VAC function assigned (Only requires a brief activation).
Vacation mode can also be turned on or off manually by
editing the VACATION MODE parameter. DCB-05V2 can
be instructed, via the pedestrian control feature, to partly
open and provide pedestrian access but prevent vehicle
access. This is achieved by partly opening the motor 1
gate leaf. If dual motors are used, motor 2’s gate leaf is
held closed. The partly open position of motor 1’s gate
leaf is initially set to a position halfway between open and
closed. This initial position can be adjusted by the installer
to any position within the gates travel range by selecting
a pedestrian access travel time (from closed). The setting
is accessed from “MENU 10.4 Set Pedestrian”. The time is
adjustable in 1 second steps
Menu 7.10 Remote Code
The controller supports the Remote Code Set feature. This
parameter can be used to disable the feature for security or
transmitter management reasons.
Menu 7.11 Battery / Solar Mode
The controller can be instructed to turn off the Battery
Backup / Solar facilities so that the control board can be
shut down without having to disconnect the Battery Backup
/ Solar system.
Menu 7.12 Password Protection
The password feature enables all parameters and
configuration settings to be protected unless a password
is entered. When this feature is turned on, the user is
requested to enter the desired password to be used. The
password protection feature has a time-out that expires
after 60 seconds of inactivity. Alternatively, the user may
log out manually by pressing exit when the main screen is
displayed.
Menu 7.13 Transmitter Grouping
The transmitter store number display format can be
changed to show a grouped format. When grouping is
selected, instead of displaying the store location as a
number between 1 and 511, it will display as ##$ where ##
is the group number and $ is a character a,b,c,d,e,f,g or h
which indicates the group member.
Menu 7.14 Output1 Mode
AUX output can be selected to be driven by:
i. Lock Drive:
Lock output can be programmed for both
hold and pulse mode. The operation of the lock can
be programmed to activate prior to the gate and
behave differently on open cycles to that on close
cycle
.
ii. Light Drive:
a light relay module can be connected on
the console between V+ and OUT2 terminal which will
turn the courtesy light on and off.
iii. 3 Wire Safety Beam 0V:
iv. Not Used