background image

 

Owner Installation Instructions 

DCB-05V2 Gate Controller

23

Parameter

Min

Max

Default

Menu 

Section

Menu 8 - Diagnostics

TEST INPUTS - Controls input display status

Inactive

8.1

Appendix D

TEST TRANSMITTERS (TX’ERS)

8.2

Appendix D

DISPLAY HISTORY

8.3

Appendix D

MEMORY USAGE

8.4

Appendix D

SERVICE COUNTER

60,000

8.5

Appendix D

EVENT COUNTER

8.6

Appendix D

Menu 9 - Memory Tools

CLR CONTROL

9.1

Appendix E

CLR TRANSMITTERS (TX’ERS)

9.2

Appendix E

Menu 10 - Setup Travel

SETUP LIMITS

10.1

8.1

TIME TRAVELED

10.2

Appendix H

REPROFILE TRAVEL

10.3

9.5

SET PEDESTRIAN

10.4

12.1

The standard operation of the opener can be altered by editing various parameters. This section describes the parameters 

and the effect they have. Use the VIEWING AND EDITING PARAMETER PROCEDURE (Appendix B) to make changes. 

C - Control Board Adjustments

Appendix 

Menu 6. Motor settings 

Motor speed

The motor settings adjust various aspects of the gate travel. 

When a single gate installation is used the SYNC DELAY 

TIMES and M2 settings are ignored.  The default value for 

the CLOSE SYNC DELAY time is automatically calculated 

for LIMIT SWITCH/AMP TRAVEL installations. The value 

calculated is selected so that the delay between M2 and 

M1 reaching the close position is equal to the OPEN SYNC 

DELAY TIME. The MAX OVERRUN TIME is set to 0 for 

TIMED TRAVEL installations.

Menu 7. Operating Modes 

Menu 7.1 First (SB1) Safety Beam Type

Select what type of Safety Beam (2 WIRE or 3 WIRE). 2 

WIRE is default.

Menu 7.2 Second (SB2) Safety Beam Type

Select what type of Safety Beam (2 WIRE or 3 WIRE). 2 

WIRE is default.

Menu 7.3 First (SB1) Safety Beam Response Mode 

The Safety Beams input can be configured to respond in 

one of eight modes.

i.    Not Used

ii.     Close to Reverse 

In this mode, the Safety Beam 

input has no effect when opening but will cause the 

gate to    

reverse if activated when closing. 

iii.     Close to Stop 

In this mode, the Safety Beam input 

has no effect when opening but will stop the gate 

when  

 

closing.

iv.     Open and Close to Stop 

In this mode, all cycles are 

prevented from being completed or initiated when 

the  

 

Safety Beam input is active

.

v.     Open input  

In this mode, open cycle is initiated 

when the Safety Beam is activated.

vi.     Swipe input  

In this mode, open cycle is initiated 

when the Safety Beam is activated.

vii.    Close input 

 In this mode, close cycle is initiated 

when the Safety Beam is activated.

viii.  Ped input 

 In this mode, ped cycle is initiated when 

the Safety Beam is activated.

ix.     Disabled   

In this mode, Safety Beam is disabled.

Menu 7.4 Second Safety Beam (SB2) Response Mode

Same as above menu 7.3

Menu 7.5 PED Input Function 

If GPI or Fire Input is selected as PED then these inputs 

can be configured to a SWIPE type input for pedestrian 

access. This provides full functionality with the Safety Beam 

Triggered Pedestrian Auto-Close function. 

Menu 7.6 Open (Opn) Input 

(Activated by OPN terminal with N/O switch, by transmitter 

button with OPN function assigned or by console’s UP 

button) Activating the OPN input will cause the gate to 

open. Holding the input will prevent closing.

Menu 7.7 Stop (STP) Input 

(Activated by STP terminal with N/O switch, by transmitter 

button with STP function assigned or by console’s EXIT 

button) Activating the STP input while the gate is moving 

will cause the gate to be stopped. If the STP terminal is 

held it will prevent the gate from being moved.

Menu 7.8 AUX Input

Is Default to Light, however can be changed to Motor 

Engaged.

Menu 7.9 Vacation Mode

Vacation mode can be turned on or off using this parameter. 

DCB-05V2 supports a Vacation mode where remote control 

access is disabled. The mode is activated by pressing a 

transmitter button with the VAC function assigned until the 

console displays that vacation mode is enabled (approx. 

5 seconds). When activated any transmitter button which 

is assigned VAC will be ignored. To turn the Vacation 

mode off, simple press a transmitter button with the 

VAC function assigned (Only requires a brief activation). 

Vacation mode can also be turned on or off manually by 

editing the VACATION MODE parameter. DCB-05V2 can 

be instructed, via the pedestrian control feature, to partly 

open and provide pedestrian access but prevent vehicle 

access. This is achieved by partly opening the motor 1 

gate leaf. If dual motors are used, motor 2’s gate leaf is 

held closed. The  partly open position of motor 1’s gate 

leaf is initially set to a position halfway between open and 

closed. This initial position can be adjusted by the installer 

to any position within the gates travel range by selecting 

a pedestrian access travel time (from closed). The setting 

is accessed from “MENU 10.4 Set Pedestrian”. The time is 

adjustable in 1 second steps

Menu 7.10 Remote Code 

The controller supports the Remote Code Set feature. This 

parameter can be used to disable the feature for security or 

transmitter management reasons.

Menu 7.11 Battery / Solar Mode

The controller can be instructed to turn off the Battery 

Backup / Solar facilities so that the control board can be 

shut down without having to disconnect the Battery Backup 

/ Solar system.

Menu 7.12 Password Protection 

The password feature enables all parameters and 

configuration settings to be protected unless a password 

is entered. When this feature is turned on, the user is 

requested to enter the desired password to be used. The 

password protection feature has a time-out that expires 

after 60 seconds of inactivity. Alternatively, the user may 

log out manually by pressing exit when the main screen is 

displayed. 

Menu 7.13 Transmitter Grouping 

The transmitter store number display format can be 

changed to show a grouped format. When grouping is 

selected, instead of displaying the store location as a 

number between 1 and 511, it will display as ##$ where ## 

is the group number and $ is a character a,b,c,d,e,f,g or h 

which indicates the group member.

Menu 7.14 Output1 Mode

AUX output can be selected to be driven by: 

i.    Lock Drive: 

Lock output can be programmed for both 

hold and pulse mode. The operation of the lock can  

  be programmed to activate prior to the gate and 

behave differently on open cycles to that on close 

cycle

.

ii.    Light Drive:

 a light relay module can be connected on 

the console between V+ and OUT2 terminal which will  

  turn the courtesy light on and off.

iii.    3 Wire Safety Beam 0V: 

iv.    Not  Used

Содержание DCB-05V2

Страница 1: ...Dual Gate Controller 24 Volt Gate Control System DCB 05V2 Doc 160020_04 Part 13314 Released 02 06 15...

Страница 2: ...9 8 Setting Limits 10 8 1 Setting Travel Limits 10 8 2 Adjusting Close Limit s 10 8 3 Adjusting Open Limit s 10 8 4 Automatic Profiling 10 8 5 Code A Transmitter For Limit Setting 11 8 6 Setting Limi...

Страница 3: ...installed by a qualified electrical contractor CAUTION Entrapment from operating gate DO NOT operate the gate opener unless the gate is in full view and free from objects such as cars and children peo...

Страница 4: ...T 1 N C relay contact OUT 1 COM relay contact OUT 1 N O relay contact MOTOR 2 terminal 1 MOTOR 2 terminal 2 MOTOR 2 close limit switch input terminal MOTOR 2 open limit switch input terminal COM termi...

Страница 5: ...vere injury Follow ALL installation instructions CAUTION do not use any cables which carry green yellow wires as this signifies earth and do not comply with electrical authority regulations 4 1 Mounti...

Страница 6: ...sed by swapping the motor connections An opportunity to confirm the correct motor polarity is provided during the limit setup procedure MI Close MOTOR 2 TERMINAL 1 MOTOR 2 TERMINAL 2 MOTOR 2 CLOSE LIM...

Страница 7: ...g 6 2 Fig 6 3 6 1 Wiring motors and limit switches DCB 05V2 can be connected to the dual gate drive units in one of several ways Wiring Figure 5 Wire Dual Gate 6 1 3 Wire Dual Gate 6 2 2 Wire Dual Gat...

Страница 8: ...OR 1 TERMINAL 1 MOTOR 1 TERMINAL 2 V PWR FOR ACCESSORIES OV Red Black White Blue Orang e Black White Orang e Red Blue Fig 6 4 6 3 Dual NeoSlider Kit This section illustrates how to wire two NeoSliderT...

Страница 9: ...cord for damage and ensure it cannot become entangled in any moving parts 7 2 Powering up the DCB 05V2 a After checking the initial wiring apply power to the DCB 05V2 The controller will go through a...

Страница 10: ...se limit and for the limit switches to be adjusted so that the motor stops at the desired position b Drive the motor using the UP and DOWN arrows on the console keypad Fig 8 4 c After making adjustmen...

Страница 11: ...me transmitter button again as prompted by display d Press the SET button to store the transmitter Navigating To Set Gate Travel Menu a Press PREV to navigate to Menu 10 b Press SET to display MENU 10...

Страница 12: ...mps 0 7 PRESS Fig 9 2 Fig 9 3 9 3 Force Pressure For Close Cycle Navigating To Current Trips a Press NEXT or PREV to navigate to Menu 2 Current Trips b Press SET Fig 9 2 c MENU 2 1 CLOSE Margin is dis...

Страница 13: ...or the button Available functions VAC Vacation Mode LGT Courtesy Light STP Stop OPN Open CLS Close SWP Swipe PED Pedestrian access OSC Open Stop Close OFF No action Press SET to save the settings or E...

Страница 14: ...re a transmitter can be used to complete the pedestrian position setting procedure 12 1 Setting the Pedestrian Position Navigating to Menu 10 4 Set Pedestrian a Press PREV to navigate to Menu 10 b Pre...

Страница 15: ...to Close mode and combinations are One Beam only i Safety Beam 1 ii Safety Beam 2 Either Beam i Safety Beam 1 or Safety Beam 2 Combination ii Safety Beam 1 and Safety Beam 2 iii Safety Beam 2 then Saf...

Страница 16: ...to activate an optional external relay module RO 1 which in turn is used to switch the load 14 1 Fitting Solenoid Or Magnetic Locks Installthelockmechanismonthegateasperthemanufacturers instructions S...

Страница 17: ...local regulations for appropriate disposal of the batteries Recycling all batteries will have other environmental and social benefits Some batteries are less toxic but hazardous for other reasons Lit...

Страница 18: ...Section 15 Antenna behind structure gate or fence or not in line of sight Ensure Antenna is in line of sight Section 4 2 Gate does not close with transmitter Safety Beam not working properly Make sure...

Страница 19: ...pendix H Maximum startup amps sets maximum permitted starting current of motors 0 0 6 0 5 0 0 1 AMPS 2 9 Appendix H Parameter timed travel Cutout AMPS maximum motor current permitted after startup 0 0...

Страница 20: ...D VOLTS Voltage applied to motors when closing 12 24 20 1 VOLTS 6 4 SLOW SPEED VOLTS Voltage applied to motors when slowing down 6 24 8 1 VOLTS 6 5 SLOW TIME The time between slow down and end of cycl...

Страница 21: ...ff 7 5 Appendix C OPN INPUT N C OPERATION Selects operating polarity of OPN input Off On Off 7 6 Appendix C STP INPUT N C OPERATION Selects operating polarity of STP input Off On Off 7 7 Appendix C AU...

Страница 22: ...EEN 2 Close Lock Time SEC 0 5 2 Close Lock Time SEC 0 5 Fig B 1 Fig B 2 B Viewing and Editing Parameters Appendix Parameter name Parameter value Displays next parameter in list Parameter number in lis...

Страница 23: ...gate to be stopped If the STP terminal is held it will prevent the gate from being moved Menu 7 8 AUX Input Is Default to Light however can be changed to Motor Engaged Menu 7 9 Vacation Mode Vacation...

Страница 24: ...he transmitter button is stored in the DCB 05V2 s memory and has a function assigned to it a second screen will be displayed that shows the transmitter details along with the button pressed Fig D 4 Th...

Страница 25: ...unter which can be set to expire after a number of drive cycles When expired DCB 05V2 will beep at the beginning of each drive cycle and a message will be displayed on the MAIN SCREEN Fig D 7 This too...

Страница 26: ...F will prevent the opener responding to that button Available functions VAC Vacation Mode LGT Courtesy Light STP Stop OPN Open CLS Close SWP Swipe PED Pedestrian access OSC Open Stop Close OFF No acti...

Страница 27: ...within memory Once located a stored transmitter can be replaced deleted edited copied or if the location is empty a new transmitter can be coded Method 1 Go To The Start Of The List Accessing The List...

Страница 28: ...ts steps 2 3 of the BASIC CODE TRANSMITTER PROCEDURE for each transmitter to be coded Coding is terminated by pressing the EXIT button Exiting The List To exit the transmitter list simply press EXIT t...

Страница 29: ...af is in the open position c Press SET to confirm or press EXIT to go back and drive the gate open Fig H 4 Automatic Profiling AfterabriefpauseDCB 05V2willautomaticallycloseandopengate several times a...

Страница 30: ...to select the correct number and then press SET Selecting Setup Method a DCB 05V2 will now prompt for the setup procedure to be selected There are 2 methods Fig I 2 i DRIVE MOTORS Press SET to continu...

Страница 31: ...his Warranty excludes damage resulting from a normal wear and tear b accidental damage c incorrect installation of the Product d blown fuses electrical surges power surges or power spikes e theft fire...

Страница 32: ...ode 128 is a trademark of Automatic Technology Australia Pty Ltd No part of this document may be reproduced without prior permission In an ongoing commitment to product quality we reserve the right to...

Отзывы: