19. Appendix
A - Console Menu Structure
Parameter
Min
Max
Default
Step
Unit
Menu
Section
Menu 1 - Code Transmitter
STORING TRANSMITTERS
0.0
511
1
10.1
Menu 2 - Current Trips
Parameter (Limit Switch)
M1 MARGIN
Sets obstruction detection margin for M1
0.0
5.0
0.7
0.1
AMPS
2.1
9.3
M2 MARGIN
Sets obstruction detection margin for M2
0.0
5.0
0.7
0.1
AMPS
2.2
9.3
SETTLE TIME disable the obstruction detection in the start of the
cycle
0.1
2.0
1.0
0.1
SEC
2.3
Parameter (AMP Limits
STOP DETECT MARGIN AMPS
0.0
5.0
1.5
0.1
AMPS
2.4
Appendix H
Motor 1 Open Limit AMPS Sets Motor 1 open limit detection current
0.0
8.0
AUTO
0.1
AMPS
2.5
Appendix H
Motor 1 Close Limit AMPS Sets Motor 1 close limit detection current
0.0
8.0
AUTO
0.1
AMPS
2.6
Appendix H
Motor 2 Open Limit AMPS Sets Motor 2 open limit detection current
0.0
8.0
AUTO
0.1
AMPS
2.7
Appendix H
Motor 2 Close Limit AMPS Sets Motor 2 close limit detection current
0.0
8.0
AUTO
0.1
AMPS
2.8
Appendix H
Maximum startup amps sets maximum permitted starting current of
motors
0.0
6.0
5.0
0.1
AMPS
2.9
Appendix H
Parameter (timed travel)
Cutout AMPS maximum motor current permitted after startup
0.0
10.0
10.0
0.1
AMPS
2.10
Appendix H
Menu 3 - Auto Close
STD AUTO-CLOSE TIME
Sets and enables the standard Auto-Close time
0.0
300.0
0.0
1.0
Sec
3.1
13.1
SAFETY BEAM AUTO-CLOSE TIME Sets and enables the SB
triggered Auto-Close time
0.0
60.0
0.0
1.0
Sec
3.2
13.2
PEDESTRIAN AUTO-CLOSE TIME Sets and enables the Pedestrian
Auto-Close time
0.0
60.0
0.0
1.0
Sec
3.3
13.3
SAFETY BEAM PEDESTRIAN AUTO-CLOSE TIME Sets and
enables the SB Pedestrian Auto-Close time
0.0
60.0
0.0
1.0
Sec
3.4
13.3
AUTO-CLOSE AFTER CLOSE OBSTRUCTION
Enables Auto-Close feature after close obstructions
Off
On
Off
3.5
13.4
AUTO-CLOSE AFTER OPEN OBSTRUCTION
Enables Auto-Close feature after open obstructions
Off
On
Off
3.6
13.4
AUTOCLOSE AFTER POWERUP
Enables autoclose feature after powerup
Off
On
Off
3.7
13.4
Menu 4 - Lock Times
OPEN LOCK TIME Set the time the lock is activated for on open
cycles
0.0
Hold
0.5
0.1
Sec
4.1
14.1
CLOSE LOCK TIME Set the time the lock is activated for on close
cycles
0.0
Hold
0.5
0.1
Sec
4.2
14.1
PRE-OPEN LOCK TIME Time the lock is activated for prior to
opening
0.0
25.5
0.0
0.1
Sec
4.3
14.1
PRE-CLOSE LOCK TIME Time the lock is activated for prior to
closing
0.0
25.5
0.0
0.1
Sec
4.4
14.1