Owner Installation Instructions
DCB-05V2 Gate Controller
9
7. Programming the DCB-05V2
7.1 Common Programs
The two most common programs are;
Program
Menu’s required
Function
Section
Automated Set Up
Menu 10.1
Setting the Limits
8.1
Safety Obstruction Force
9.1 and 9.2
Menu 1
Coding the Transmitter
10.1
Automated Set Up with
Safety Beams
Menu 10.1
Setting the Limits
8.1
Safety Obstruction Force
9.1 and 9.2
Menu 1
Coding the Transmitter
10.1
Menu 3
Auto Close Times
13.2, 13.3 and 13.4
NOTE:
Fitting Safety Beams enables the Auto-Close feature to become active.
CAUTION: Before plugging the gate control system
in, check the power cord for damage and ensure it
cannot become entangled in any moving parts
7.2 Powering up the DCB-05V2
a. After checking the initial wiring, apply power to the DCB-05V2.
The controller will go through a startup sequence displaying
the STARTUP SCREEN which indicates the controller type
and firmware version
(Fig. 7.2)
.
After a short delay the MAIN
SCREEN will be displayed.
b. If this is the first time the DCB-05V2 has been used, the MAIN
SCREEN should indicate that the limits are not set
(Fig. 7.3)
.
If the display shows that some input is active then rectify
the situation before proceeding. If a default setting is to be
changed it should be done now before setting the travel limits.
A.T.A GCS24
FIRMWARE X.XX
PREV
NEXT
EXIT
SET
Limits Not Set!
Press <> To Acess MENU
PREV
NEXT
EXIT
SET
Start up screen
Main screen
Fig 7.2
Fig 7.3
Fig 7.1