Owner Installation Instructions
DCB-05V2 Gate Controller
7
Fig 5.1
Fig 5.2
Fig 5.3
6. Wiring Diagrams - Dual Gates
MOTOR 2 TERMINAL 1
MOTOR 2 TERMINAL 2
MOTOR 2 CLOSE LIMIT SWITCH INPUT
MOTOR 2 OPEN LIMIT SWITCH INPUT
COMMON FOR MOTOR 1 & 2 LIMIT SWITCHES
MOTOR 1 CLOSE LIMIT SWITCH INPUT
MOTOR 1 OPEN LIMIT SWITCH INPUT
MOTOR 1 TERMINAL 1
MOTOR 1 TERMINAL 2
V PWR FOR ACCESSORIES
OV
MI
M2
MOTOR 2
MOTOR 1
open
close
open
close
MOTOR 2 TERMINAL 1
MOTOR 2 TERMINAL 2
MOTOR 2 CLOSE LIMIT SWITCH INPUT
MOTOR 2 OPEN LIMIT SWITCH INPUT
COMMON FOR MOTOR 1 & 2 LIMIT SWITCHES
MOTOR 1 CLOSE LIMIT SWITCH INPUT
MOTOR 1 OPEN LIMIT SWITCH INPUT
MOTOR 1 TERMINAL 1
MOTOR 1 TERMINAL 2
V PWR FOR ACCESSORIES
OV
M1
M2
MOTOR 1
1N4004 diode
open
close
1N4004 diode
1N4004 diode
open
close
1N4004 diode
MOTOR 2
MOTOR 2 TERMINAL 1
MOTOR 2 TERMINAL 2
MOTOR 2 CLOSE LIMIT SWITCH INPUT
MOTOR 2 OPEN LIMIT SWITCH INPUT
COMMON FOR MOTOR 1 & 2 LIMIT SWITCHES
MOTOR 1 CLOSE LIMIT SWITCH INPUT
MOTOR 1 OPEN LIMIT SWITCH INPUT
MOTOR 1 TERMINAL 1
MOTOR 1 TERMINAL 2
V PWR FOR ACCESSORIES
OV
MI
MOTOR 1
M2
MOTOR 2
Fig 6.1
Fig 6.2
Fig 6.3
6.1 Wiring motors and limit switches
DCB-05V2 can be connected to the dual gate
drive units in one of several ways.
Wiring
Figure #
5 Wire Dual Gate
6.1
3 Wire Dual Gate
6.2
2 Wire Dual Gate
6.3
The diagrams
(Fig. 6.1 to Fig. 6.3)
show the
various wiring methods used for different drive
unit types. Select the appropriate method for
your drive unit.
NOTE:
“non-motor current carrying limit-
switch” type drive units can be connected using
the standard 5 wire connections or a special
3 wire method that uses a single limit switch
sense wire and four diodes.
6.2 Diodes 1N4004 or equivalent
(not included)
The most common function of a diode is to allow
an electric current to pass in one direction and
to block the current in the opposite direction.
The diode is a unidirectional electronic
component. It must be used as shown in
Fig. 5.2
to work properly.
NOTE:
the drive unit connected to the MOTOR
1 terminals will open first and will be used for
pedestrian access.
NOTE:
The motor travel direction can be
reversed by swapping the motor connections. An
opportunity to confirm the correct motor polarity
is provided during the limit setup procedure.
CAUTION: Cables which have a green/yellow coloured insulation are for earthing purposes only.
Never use these cables for any other purpose.