DCB-05V2 Gate Controller 

Owner Installation Instructions

PRESS

New 
transmitter

Fig 11.3

NOTE: 

When a transmitter is remotely coded, its ID label is set to that 

of the existing transmitter. If the existing transmitter does not have an 

ID label assigned, then the ID label of the new transmitter is set to: 

R/C Tx ###, where ### is the existing transmitters store number. This 

ensures that the originator of any remotely coded transmitter can be 

identified.

DCB-05V2 can be instructed, via its pedestrian control feature, to partly open and provide pedestrian access but prevent 

vehicle access. This is achieved by partly opening the motor 1 gate leaf. If dual motors are used, motor 2’s gate leaf is 

held closed. The partly open position of motor 1’s gate leaf is initially set to a position halfway between open and closed. 

This initial position can be adjusted by the installer to any position within the gates travel range by selecting a pedestrian 

access travel time (from closed). The setting is accessed from “MENU 10.4 Set Pedestrian”. The time is adjustable in  

1 second steps. 

12. Setting Pedestrian Position

PED’N Opening
TIME               5

PREV

NEXT

EXIT

SET

Fig 12.1

Fig 12.2

MENU 10.4
SET PEDESTRIAN

PREV

NEXT

EXIT

SET

PRESS

NOTE: 

Before setting the pedestrian access position the gate 

must be in the fully closed position. As with the Setting Travel 

Limit procedure, a transmitter can be used to complete the 

pedestrian position setting procedure.

12.1 Setting the Pedestrian Position

Navigating to “Menu 10.4 Set Pedestrian” 

a. Press PREV to navigate to Menu 10. 

b. Press SET - MENU 10.1 is displayed. 

c. Press NEXT to go to MENU 10.4. 

d. Press SET to enter Set Pedestrian procedure

 

(Fig. 12.1)

Setting pedestrian position 

a. Press UP or DOWN arrows to adjust pedestrian drive time. 

b. Press SET to record position  

c. Press transmitter coded for pedestrian function or push button 

wired into pedestrian input to test.

12.2 Checking Pedestrian Position 

When activated by a transmitter button which is coded as Ped 

mode, the opener drives the gate to the preset position. Ped 

Mode’s active status is indicated on the display 

(Fig. 12.2)

.

 If a 

Ped Mode button is pressed while the gate is moving, the gate 

will stop. If a Ped Mode button is pressed when the gate is in the 

Ped position, then the gate will close.

12.3 Error Displays

During the above procedure many error checks are performed. If 

an error is detected, a message will be displayed indicating the 

error. 

11.2 Activate Remote Code Set Mode 

a. Use a small pin to press and hold through the Coding Hole of the 

existing transmitter for 2 seconds

 

(Fig. 11.2)

b. Within 10 seconds, press the button on the new transmitter you 

wish to code for 2 seconds

 

(Fig. 11.3)

c. Press the same button again (within 10 seconds)for confirmation. 

d. Test Operation. The new transmitter button should now function as 

the existing transmitter. 

11. Remotely Coding Transmitters

Existing 
transmitter

Fig 11.2

Содержание DCB-05V2

Страница 1: ...Dual Gate Controller 24 Volt Gate Control System DCB 05V2 Doc 160020_04 Part 13314 Released 02 06 15...

Страница 2: ...9 8 Setting Limits 10 8 1 Setting Travel Limits 10 8 2 Adjusting Close Limit s 10 8 3 Adjusting Open Limit s 10 8 4 Automatic Profiling 10 8 5 Code A Transmitter For Limit Setting 11 8 6 Setting Limi...

Страница 3: ...installed by a qualified electrical contractor CAUTION Entrapment from operating gate DO NOT operate the gate opener unless the gate is in full view and free from objects such as cars and children peo...

Страница 4: ...T 1 N C relay contact OUT 1 COM relay contact OUT 1 N O relay contact MOTOR 2 terminal 1 MOTOR 2 terminal 2 MOTOR 2 close limit switch input terminal MOTOR 2 open limit switch input terminal COM termi...

Страница 5: ...vere injury Follow ALL installation instructions CAUTION do not use any cables which carry green yellow wires as this signifies earth and do not comply with electrical authority regulations 4 1 Mounti...

Страница 6: ...sed by swapping the motor connections An opportunity to confirm the correct motor polarity is provided during the limit setup procedure MI Close MOTOR 2 TERMINAL 1 MOTOR 2 TERMINAL 2 MOTOR 2 CLOSE LIM...

Страница 7: ...g 6 2 Fig 6 3 6 1 Wiring motors and limit switches DCB 05V2 can be connected to the dual gate drive units in one of several ways Wiring Figure 5 Wire Dual Gate 6 1 3 Wire Dual Gate 6 2 2 Wire Dual Gat...

Страница 8: ...OR 1 TERMINAL 1 MOTOR 1 TERMINAL 2 V PWR FOR ACCESSORIES OV Red Black White Blue Orang e Black White Orang e Red Blue Fig 6 4 6 3 Dual NeoSlider Kit This section illustrates how to wire two NeoSliderT...

Страница 9: ...cord for damage and ensure it cannot become entangled in any moving parts 7 2 Powering up the DCB 05V2 a After checking the initial wiring apply power to the DCB 05V2 The controller will go through a...

Страница 10: ...se limit and for the limit switches to be adjusted so that the motor stops at the desired position b Drive the motor using the UP and DOWN arrows on the console keypad Fig 8 4 c After making adjustmen...

Страница 11: ...me transmitter button again as prompted by display d Press the SET button to store the transmitter Navigating To Set Gate Travel Menu a Press PREV to navigate to Menu 10 b Press SET to display MENU 10...

Страница 12: ...mps 0 7 PRESS Fig 9 2 Fig 9 3 9 3 Force Pressure For Close Cycle Navigating To Current Trips a Press NEXT or PREV to navigate to Menu 2 Current Trips b Press SET Fig 9 2 c MENU 2 1 CLOSE Margin is dis...

Страница 13: ...or the button Available functions VAC Vacation Mode LGT Courtesy Light STP Stop OPN Open CLS Close SWP Swipe PED Pedestrian access OSC Open Stop Close OFF No action Press SET to save the settings or E...

Страница 14: ...re a transmitter can be used to complete the pedestrian position setting procedure 12 1 Setting the Pedestrian Position Navigating to Menu 10 4 Set Pedestrian a Press PREV to navigate to Menu 10 b Pre...

Страница 15: ...to Close mode and combinations are One Beam only i Safety Beam 1 ii Safety Beam 2 Either Beam i Safety Beam 1 or Safety Beam 2 Combination ii Safety Beam 1 and Safety Beam 2 iii Safety Beam 2 then Saf...

Страница 16: ...to activate an optional external relay module RO 1 which in turn is used to switch the load 14 1 Fitting Solenoid Or Magnetic Locks Installthelockmechanismonthegateasperthemanufacturers instructions S...

Страница 17: ...local regulations for appropriate disposal of the batteries Recycling all batteries will have other environmental and social benefits Some batteries are less toxic but hazardous for other reasons Lit...

Страница 18: ...Section 15 Antenna behind structure gate or fence or not in line of sight Ensure Antenna is in line of sight Section 4 2 Gate does not close with transmitter Safety Beam not working properly Make sure...

Страница 19: ...pendix H Maximum startup amps sets maximum permitted starting current of motors 0 0 6 0 5 0 0 1 AMPS 2 9 Appendix H Parameter timed travel Cutout AMPS maximum motor current permitted after startup 0 0...

Страница 20: ...D VOLTS Voltage applied to motors when closing 12 24 20 1 VOLTS 6 4 SLOW SPEED VOLTS Voltage applied to motors when slowing down 6 24 8 1 VOLTS 6 5 SLOW TIME The time between slow down and end of cycl...

Страница 21: ...ff 7 5 Appendix C OPN INPUT N C OPERATION Selects operating polarity of OPN input Off On Off 7 6 Appendix C STP INPUT N C OPERATION Selects operating polarity of STP input Off On Off 7 7 Appendix C AU...

Страница 22: ...EEN 2 Close Lock Time SEC 0 5 2 Close Lock Time SEC 0 5 Fig B 1 Fig B 2 B Viewing and Editing Parameters Appendix Parameter name Parameter value Displays next parameter in list Parameter number in lis...

Страница 23: ...gate to be stopped If the STP terminal is held it will prevent the gate from being moved Menu 7 8 AUX Input Is Default to Light however can be changed to Motor Engaged Menu 7 9 Vacation Mode Vacation...

Страница 24: ...he transmitter button is stored in the DCB 05V2 s memory and has a function assigned to it a second screen will be displayed that shows the transmitter details along with the button pressed Fig D 4 Th...

Страница 25: ...unter which can be set to expire after a number of drive cycles When expired DCB 05V2 will beep at the beginning of each drive cycle and a message will be displayed on the MAIN SCREEN Fig D 7 This too...

Страница 26: ...F will prevent the opener responding to that button Available functions VAC Vacation Mode LGT Courtesy Light STP Stop OPN Open CLS Close SWP Swipe PED Pedestrian access OSC Open Stop Close OFF No acti...

Страница 27: ...within memory Once located a stored transmitter can be replaced deleted edited copied or if the location is empty a new transmitter can be coded Method 1 Go To The Start Of The List Accessing The List...

Страница 28: ...ts steps 2 3 of the BASIC CODE TRANSMITTER PROCEDURE for each transmitter to be coded Coding is terminated by pressing the EXIT button Exiting The List To exit the transmitter list simply press EXIT t...

Страница 29: ...af is in the open position c Press SET to confirm or press EXIT to go back and drive the gate open Fig H 4 Automatic Profiling AfterabriefpauseDCB 05V2willautomaticallycloseandopengate several times a...

Страница 30: ...to select the correct number and then press SET Selecting Setup Method a DCB 05V2 will now prompt for the setup procedure to be selected There are 2 methods Fig I 2 i DRIVE MOTORS Press SET to continu...

Страница 31: ...his Warranty excludes damage resulting from a normal wear and tear b accidental damage c incorrect installation of the Product d blown fuses electrical surges power surges or power spikes e theft fire...

Страница 32: ...ode 128 is a trademark of Automatic Technology Australia Pty Ltd No part of this document may be reproduced without prior permission In an ongoing commitment to product quality we reserve the right to...

Отзывы: