NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
INNOVATIVE HEARTH PRODUCTS • LINEAR GAS FIREPLACES • REQUIRED AND OPTIONAL ACCESSORIES
5
CONNECTION AND ROUTE WIRING FOR OPTIONAL PANEL
BACKLIGHT KIT - SIT PROFLAME II SYSTEM
1.
After accessing the control compartment (see
Page 3
,
Figure
6
)
, use a screwdriver or similar object to carefully break the
sealant around the wires, taking care not to nick the wires.
2.
Plug in the Multi-wire Harness (provided with the Panel
Backlight Kit) into the SimFlame module port with the red
wires
(
Figures 8 and 12
)
and the light wire harness into the
light module harness.
3.
Plug in the light wire harness (provided with the Panel
Backlight Kit) into the SimFlame Module port with the black
and white wires.
NOTE: If NOT installing the SimFlame (fl icker) Module,
plug the Multi-Wire Harness directly into the light wire
harness (omitting the components outlined in
Figure 8
)
4.
Route the wiring up through the access opening and slide it
into the slot
(
Figure 14
)
.
5.
Attach the wiring to each lamp assembly as described
below and shown in
Figure 17
:
a. Route one set of three leads (white/green/black)
through the hole in the front of the bracket.
b. Connect the green wire as shown in
Figure 17
.
c. Insert the lamp (with green wire attached) into the
bracket until the spring clip is engaged.
d. Attach the white (neutral) and black (hot) wires as
shown
in
Figure 17.
6.
Carefully lay the Panel Backlight lamp assemblies and
wiring on the fi replace fl oor. The lamp assemblies will not
be installed until the back panel is installed (In Step 9,
Figure 18 on Page 6
).
Figure 12 - Connecting the SIT PF II Module
Light Wire Harness
Light Module Harness
PF2 Module
SimFlame Module
Multi-Wire Harness
Red Wires
Install back panel
1.
Insert the bottom edge of the back panel into the fi replace
fi rst, then position it in front of the previously installed
refl ector
(
Figure 13
)
.
NOTE:
Lift the back panel over the tabs on the rear ledge of
the fi replace.
2.
Align the screw holes in the top and bottom edges of the
back panel with the holes in the fi replace ceiling and rear
ledge. Secure using seven (7) #10-16 x 3/8 hex-head sheet
metal screws provided with the fi rebox panel kit.
~
Fireplace
Front
Left Side
Panel
Back Panel
Refl ector
Tab
Rear Ledge
Figure 13 - Installing the back panel
Route wiring for optional blower kit
NOTE:
Use only original, factory-supplied wiring inside the
fi replace. See the wiring diagrams on
Page 11
.
1.
Route the wiring per the instructions (P/N 750028M).
Route wiring for optional power vent kit
NOTE:
Use only original, factory-supplied wiring inside the
fi replace. See the wiring diagrams on
Page 11
.
1.
Route the wiring per instructions (P/N 506022-01).
Determine optional fi rebox panel backlight kit wire
routing method
There are two approved methods for routing the wiring for the
optional fi rebox panel backlight kit.
The preferred method is outlined in the following sections. The
alternate method is included for installations where the fi rebox
rear ledge does not have backlight wire routing holes, and is
described in the Appendix section
Route and connect optional
fi rebox panel backlight kit wiring and install lamp assemblies
as shown on
Page 6
.
1.
Determine whether the fi rebox rear ledge has backlight wire
routing holes
(
Figure 14
).
f i r e - p a r t s . c o m