Astria Fireplaces Rhapsody42 Series Скачать руководство пользователя страница 1

NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.

HEARTH PRODUCTS

KITS AND ACCESSORIES

P/N 900077-05
Rev. A  09/2016

LINEAR DIRECT-VENT FIREPLACES 

ACCESSORY KITS

INSTALLATION INSTRUCTIONS FOR REQUIRED AND OPTIONAL ACCESSORIES
FOR USE ON 42- AND 54-INCH LINEAR DIRECT-VENT GAS FIREPLACES

[FIREPLACE MODELS: Rhapsody42 and Rhapsody54 Series]

 DANGER

HOT GLASS WILL CAUSE BURNS. DO NOT 

TOUCH GLASS UNTIL COOLED. NEVER 

ALLOW CHILDREN TO TOUCH GLASS.

•  Fireplaces surfaces get EXTREMELY HOT!
•  Install only when fi replace is OFF and COLD.

•  The glass on the front of the fi replace reaches 

EXTREMELY HIGH temperatures and can cause severe 
burns if touched. Even after the gas is turned off, 
fi replace surfaces remain extremely hot.

•  Keep children away from an operating fi replace. Closely 

supervise children in any room where a fi replace is 
operating to prevent contact with glass. 

 

CAUTION

RISK OF PERSONAL INJURY OR PROPERTY DAMAGE. 

•  Never operate fireplace without liner panels installed. These 

appliances are NOT approved for operation without liner panels.

•  Do NOT abuse glass doors by striking or slamming shut
•  Never operate fi replace with glass door assembly removed.
•  Handle glass door assembly with extreme care. 

Replace damaged glass door assembly with approved 
replacement assembly only.

•  Use only media approved for use with these fi replaces 

(as applicable). Failure to use approved media may result 
in sooting, delayed ignition, or other improper fi replace 
operation, and may void the warranty.

NOTICE

•  Read all steps before starting installation. 
•  LEAVE THESE INSTRUCTIONS WITH THE APPLIANCE.
•  All warnings, precautions, and instructions in the Installation 

and Operation Instructions provided with the appliance also 
apply to these instructions.

•  If you encounter any problems, need clarifi cation of these 

instructions, or are not qualifi ed to properly install this 
kit, contact your local distributor or dealer.

Figure 1 -  54 in. Rhapsody linear gas fi replaces with 

designer fl oor kit and Illusion Cityscape fi rebox 
panel kit (both in black porcelain).

GENERAL INFORMATION

This document contains installation instructions for the following 
required and optional accessories for Rhapsody

®

 linear direct-

vent gas fi replaces manufactured by INNOVATIVE HEARTH 
PRODUCTS (IHP).

Kit descriptions, catalog/model numbers, and contents are listed 
on the next page.

Required Accessory Kits

The following accessory kits are REQUIRED for complete fi re-
place installation.

NOTE: 

Ensure these kits are available before installing the fi re-

place.

•  Firebox Panel Kit 

(Rhapsody models only)

• Floor 

Kit 

(Rhapsody models only)

•  Media Kit *

*  Media kit required with “Designer" style fl oor kits only (Rhapsody models only)

Media must not be used with Refection fl oor.

Optional Accessory Kits

The following accessories are OPTIONAL. However, to minimize 
required labor, all  options should be installed at time of fi replace 
installation, if possible.

• Surround 

Kit

• Bezel 

Kit

•  Firebox Backlight Kit ** 

(Rhapsody models only)

•  Power Vent Kit 

(see manual 506022-01 for installation instructions)

**   Firebox backlight kit for use with "Cityscape" and "Illusion" style fi rebox 

panel kits (Rhapsody models only)

REQUIRED TOOLS

NOTE: 

Power tools are NOT recommended when installing fi re-

place accessories, especially porcelain fi rebox panels.

•  5/16" Hex-head Nut Driver
•  #3 Phillips Head Screwdriver 

(for fi replace door removal/installation)

•  Glass Cleaner (non-ammoniated)
• Non-abrasive 

rag

• High-temperature 

sealant 

(e.g., Mill-Pac

®

; if installing fi rebox backlight kit)

• Safety 

Glasses

•  Protective Work Gloves

f i r e - p a r t s . c o m

Содержание Rhapsody42 Series

Страница 1: ...vided with the appliance also apply to these instructions If you encounter any problems need clarification of these instructions or are not qualified to properly install this kit contact your local di...

Страница 2: ...See media kit instructions P N 900077 07 Description Cat No Model No Reflective Black H8412 CRSHGL RBLK Reflective Blue H8424 CRSHGL RBLU Platinum H8413 CRSHGL P Goldfinger H8538 CRSHGL GF Copper H85...

Страница 3: ...es from tabs and pull directly away from the fireplace 2 To replace the barrier if damaged remove the three 3 screws from the top and bottom and one 1 screw from each side Reverse these instructions t...

Страница 4: ...hite wires Figure 9 FAN AUX OUT SimFlame Slot SimFlame Module Fan Control Module Plug blower into FAN port Plug lights into AUX OUT port Figure 9 Connecting the lights and blower 4 Route the lighting...

Страница 5: ...In Step 9 Figure 18 on Page 6 Figure 12 Connecting the SIT PF II Module Light Wire Harness Light Module Harness PF2 Module SimFlame Module Multi Wire Harness Red Wires Install back panel 1 Insert the...

Страница 6: ...ng the cover plates and routing the wiring 2 Route one set of three leads white green black through each backlight wire routing hole in the rear ledge Figure 14 3 Route one set of three leads white gr...

Страница 7: ...and a soft rag to remove fingerprints and smudges from porcelain panels and floors Install glass door assembly 1 Hold the glass door assembly by the sides and hook the top edge to the fireplace Then...

Страница 8: ...de Panel Center Lower Tab Figure 22 Installing the rear floor section Install front floor section from required floor kit 1 Engage the lower front lip of the front floor section under the locking clip...

Страница 9: ...cross the top of the fireplace lengthwise behind heat shield 5 Install top bottom and two 2 side surround support pieces with screws from step 1 see Figure 27 6 Cut top noncombustible fireboard to siz...

Страница 10: ...ently push the lower edge of the bezel to attach the bezel lower flange to the lower edge of the glass door frame CROSS SECTION Barrier Flanges Door Trim Barrier Figure 28 Place barrier screen on Beze...

Страница 11: ...PH Junction Box Field Wired Factory Wired Power Supply Unswitched Figure 31 Junction Box Wiring Pilot Tube COLOR CODE B BLACK BB BROWN W BLACK STRIPE BG BROWN W GREEN STRIPE BL BLUE BR BROWN G GREEN G...

Страница 12: ...p with green wire attached into bracket until the spring clip is engaged Figure 34 4 Connect the white neutral wire and black hot wire Figure 35 Figure 34 Attaching green wire to firebox panel backlig...