Astralpool 54568 Скачать руководство пользователя страница 13

Optiek:

2 LED, 

λ

1

 = 528 nm (filter) ; 

λ

2

 = 605 nm

Batterij:

9 V batterij (levensduur ca. 600 tests).

Auto-OFF:

automatische uitschakeling 5 minuten na laatste

toetsdruk

Omgeving:

5-40

°

C

30-90% rel. vochtigheid (niet condenserend).

CE:

DIN EN 55 022, 61 000-4-2, 61 000-4-8,
50 082-2, 50 081-1, DIN V ENV 50 140, 50 204

Technische gegevens

In bedrijf nemen

5 in 1 Fotometer:  Cl,  pH,  Cys,  TA,  CAH

Aanwijzingen voor de gebruiker

M E T H O D E

M E T H O D E

M E T H O D E

Zero

Test

M E T H O D E

M E T H O D E

M E T H O D E

M E T H O D E

M E T H O D E

M E T H O D E

0.0.0

R E S U L T A A T

R E S U L T A A T

R E S U L T A A T

Zero

Test

Mode

÷

Err

of

 HI

EOI

-Err 

of

 LO

LO BAT

ON

OFF

Cl

Chloor  0,05 - 6,0 mg/l

pH-waarde  6,5 - 8,4

0.0.0

Zero

Test

R E S U L T A A T

R E S U L T A A T

R E S U L T A A T

0.0.0

R E S U L T A A T

R E S U L T A A T

R E S U L T A A T

R E S U L T A A T

R E S U L T A A T

R E S U L T A A T

Cl

Cl

Zero

Test

Zero

Test

pH

Meter inschakelen door op de ON/OFF toets te drukken

In de display verschijnt:

Kies meetbereik met de toets MODE:
Cl

 pH 

→ 

Cys

→ 

tA

→ 

CA.H

→ 

Cl

→ 

.......... (Scroll)

In de aanwijzing verschijnt:

Vul een schoon cuvet tot de 10 ml markering met het
watermonster, sluit het af met het cuvetdeksel en plaats
het cuvet, met de 

Δ

-markering naar de 

Δ

-markering op

de meter, in de meetschacht.

Druk op de toets ZERO/TEST.

Het methode-symbool knippert ca. 3 seconden.

In de display verschijnt:

Neem na afloop van de nulstelling het cuvet uit de
meetschacht.
Door toevoeging van de reagenstablet(ten) ontstaat de
karakteristieke kleur.
Sluit het cuvet af met het deksel en zet het 

Δ

   in de

meetschacht.

Druk op de toets ZERO/TEST.

Het methode-symbool knippert ca. 3 seconden.

In de display verschijnt het meetresultaat.

Herhaling van de bepaling:

Opnieuw de toets ZERO/TEST drukken.

Opnieuw nulpunt instellen:

Druk de MODE toets tot het gewenste meetbereik
opnieuw in de display verschijnt.

Lichtabsorptie te groot. Mogelijke oorzaak: vervuilde optiek.

Meetbereik overschreden of te hoge troebelheid.

Meetbereik onderschreden.

9 V batterij direct vervangen, verder werken niet mogelijk.

(a) vrij Chloor

Doe de nulstelling (zie: In bedrijf nemen).
Doe een DPD 1 tablet direkt uit de folie in 10 ml
monsterwater en maak deze fijn met een schone roer-
staaf. Tablet geheel oplossen.
Cuvet met deksel sluiten en in de meetschacht
positioneren 

Δ

   .

Toets ZERO/TEST drukken.

Het methode-symbool knippert ca. 3 seconden.

In de display verschijnt het meetresultaat in mg/l vrij chloor.

(b) totaal Chloor

Voeg direkt na de meting aan het gekleurde monster een
DPD 3 tablet uit de folie toe, druk fijn met de roerstaaf.
Tablet geheel oplosen. Cuvet met deksel sluiten en in de
meetschacht positioneren 

Δ

   .

Twee minuten kleurreactie-tijd wachten!

Toets ZERO/TEST drukken.

Het methode-symbool knippert ca. 3 seconden.

In de display verschijnt het meetresultaat in mg/l totaal chloor.

(c) gebonden Chloor

gebonden chloor = totaal chloor - vrij chloor

Toleranties:

0-1 mg/l: 

±

 0,05 mg/l > 3-4 mg/l: 

±

 0,30 mg/l

> 1-2 mg/l: 

±

 0,10 mg/l > 4-6 mg/l: 

±

 0,40 mg/l

> 2-3 mg/l: 

±

 0,20 mg/l

Doe de nulstelling (zie: In bedrijf nemen).
Doe een PHENOLRED/PHOTOMETER tablet direkt uit
de folie in 10 ml monsterwater en maak deze fijn met
een schone roerstaaf. Tablet geheel oplossen. Cuvet met
deksel sluiten en in de meetschachtpositioneren 

Δ

   .

Het methode-symbool knippert ca. 3 seconden.

Toets ZERO/TEST drukken.

In de display verschijnt de gemeten pH-waarde.

Tolerantie: 

±

 0,1 pH

NL

Cyanuurzuur  2 - 160 mg/l

In de display verschijnt:

Een schoon cuvet tot de 5 ml markering met het
watermonster en tot de 10 ml markering met
gedemineraliseerd water vullen. Sluit het cuvet af met de
deksel en plaats het met de 

–markering naar de

Δ

-markering op de meter in de meetschacht.

Toets ZERO/TEST drukken.

Het methode-symbool knippert ca. 3 seconden.

In de display verschijnt:

•Cys

Zero

Test

•Cys

0.0.0

Doe een CYANURIC-ACID tablet direct uit de folie in
10 ml monsterwater en maak deze fijn met een schone
roerstaaf.
Tablet geheel oplossen.
Cuvet met deksel sluiten en in de meetschacht
positioneren  

Δ

 .

Toets ZERO/TEST drukken.

Het methode-symbool knippert ca. 3 seconden.

In de display verschijnt het meetresultaat in mg/l cyanuurzuur.

Tolerantie:

±

 10 mg/l

Zero

Test

•Cys

R E S U L T A A T

R E S U L T A A T

R E S U L T A A T

Doe de nulstelling (zie: in bedrijf nemen).
Voeg een ALKA-M-PHOTOMETER tablet direct uit de
folie toe en maak deze fijn met een schone roerstaaf.
Laat de tablet geheel oplossen. Sluit de cuvet met de
deksel en positioneer de cuvet in de meetschacht

Δ

 .

Druk op de toets ZERO/TEST.

Het methode-symbool knippert circa 3 seconden.

In de display verschijnt het meetresultaat in mg/l CaCO

3

.

Reinig cuvet en deksel grondig na elke meting.

Tolerantie:

±

 5% van het volledig meetbereik.

Totale alkaliteit  5 - 200 mg/l CaCO

3

0.0.0

R E S U L T

R E S U L T

R E S U L T

Zero

Test

tA

Calcium-Hardheid 50 - 500 mg/l CaCO

3

0.0.0

R E S U L T

R E S U L T

R E S U L T

Zero

Test

CA.H

Gebruik de adapter voor de 16 mm cuvet.
Vul een schone 16 mm cuvet met 8 ml gedestilleerd water
dat vrij is van calcium ionen. Voeg een CALCHECK tablet
direct uit de folie toe en maak deze fijn met een schone
roerstaaf. Laat de tablet geheel oplossen. Sluit de cuvet met
de deksel en positioneer de cuvet in de meetschacht

Δ

 .

Druk op de toets ZERO/TEST.

Het methode-symbool knippert circa 3 seconden.

In de display verschijnt:

Haal de cuvet uit de adapter en doe er 2 ml monsterwater
in. Sluit de cuvet met de deksel en positioneer de cuvet
in de meetschacht

Δ

 .

Wacht 2 minuten kleurreactietijd af!

Druk op de toets ZERO/TEST.

Het methode-symbool knippert circa 3 seconden.

In de display verschijnt het meetresultaat in mg/l CaCO

3

.

Tolerantie:

±

 5% van het volledig meetbereik.

Zero

Test

CA.H

Содержание 54568

Страница 1: ... the cap tightly and place the vial in the sample chamber making sure the Δ and marks are aligned Press the ZERO TEST key The method symbol flashes for approx 3 seconds The mg l CaCO3 value is shown in the display Rinse the vial and cap thoroughly after each test Tolerance 5 Full Scale Total Alkalinity 5 200 mg l CaCO3 0 0 0 R E S U L T R E S U L T Zero Test tA Switch the unit on using the ON OFF ...

Страница 2: ...ess both the MODE and ZERO TEST and keep them depressed Switch the unit on using the ON OFF key Release the MODE and ZERO TEST keys after approx 1 second The following messages will appear in turn on the display The calibration is reset to the factory setting SEL stands for Select or Calibration has been set by the user If the user calibration is to be retained switch the unit off using the ON OFF...

Страница 3: ...ondes Les résultat s affiche en mg l chlore total c Chlore combin Chlore combiné chlore total chlore libre Tol rance 0 1 mg l 0 05 mg l 3 4 mg l 0 30 mg l 1 2 mg l 0 10 mg l 4 6 mg l 0 40 mg l 2 3 mg l 0 20 mg l Procéder au calibrage du zéro voir Mise en service Ajouter une pastille de PHENOLRED PHOTOMETER dans l échantillon de 10 ml en la sortant directement de la feuille de protection sans la to...

Страница 4: ...de CAL Cl CAL RESULTAT x RESULTAT x Mode Zero Test 0 0 0 Zero Test R E S U L T A T R E S U L T A T CAL Zero Test On Off Remarque CAL cAL M E T H O D E M E T H O D E M E T H O D E M E T H O D E Valeures de calibrage recommand Chlore entre 0 5 et 1 5 mg l pH entre 7 6 et 8 0 Acide cyanurique entre 30 et 60 mg l Alcalinité totale entre 50 et 150 mg l CaCO3 Dureté calcique entre 100 et 200 mg l CaCO3 ...

Страница 5: ... Tolerancias 0 1 mg l 0 05 mg l 3 4 mg l 0 30 mg l 1 2 mg l 0 10 mg l 4 6 mg l 0 40 mg l 2 3 mg l 0 20 mg l Realizar la calibraci n a cero v ase instrucciones A los 10 ml de prueba acuosa a adir directamente de su envoltura una tableta PHENOLRED PHOTOMETER y machacarla con una varilla limpia Disolver completamente la tableta cerrar la cubeta con su tapa y posicionarla Δ Presionar ZERO TEST El s mb...

Страница 6: ...roduce errores de medici n En este caso se tapa la cubeta y las burbujas se disuelven girando la cubeta antes de realizar el an lisis 7 La infiltraci n de agua en la c mara de medici n debe ser evitada La entrada de agua en la caja del fot metro puede destruir las piezas de construcci n electr nicas y producir da os de corrosion 8 El ensuciamiento de la ptica diodo luminoso y fotosensor en la c ma...

Страница 7: ... de método presionar la tecla MODE CAL Cl CAL pH CAL Cys CAL S 4 3 Scroll Realizar la calibración a cero como descrito Presionar la tecla ZERO TEST El símbolo del método parpadea durante aproximadamente 3 segundos En el display aparece alternativamente Colocar el estándar a utilizar en el compartimento de medición según las marcas Presionar la tecla ZERO TEST El símbolo del método parpadea durante...

Страница 8: ...y appare il risultato in mg l del cloro totale c Cloro combinato Cloro legato cloro totale cloro libero Tolleranza 0 1 mg l 0 05 mg l 3 4 mg l 0 30 mg l 1 2 mg l 0 10 mg l 4 6 mg l 0 40 mg l 2 3 mg l 0 20 mg l Condurre la taratura a zero vedere la messa in funzione Aggiungere direttamente nei 10 ml dell acqua di prova una compressa di PHENOLRED PHOTOMETER senza toccarla con le dita e frantumarla c...

Страница 9: ... e le bollicine si dissolvono agitando la cuvetta prima di procedere al test 7 Si deve impedire la penetrazione di acqua nel pozzetto di misurazione L entrata dell acqua nel corpo del fotometro pu comportare un danneggiamento dell elettronica e danni dovuti a corrosione 8 L apparecchiatura ottica diodo luminoso e fotosensore nel pozzetto di misurazione se sporca comporta errori di misurazione Le s...

Страница 10: ...ffettuata dall operatore scorretto cancellato E 10 E 70 E 72 E 74 E 71 E 73 E 75 E 76 E 77 E 79 E 78 Calibrazione effettuata dall operatore cAL Calibrazione effettuata in fabbrica CAL Zero Test Mode On Off CAL SEL SEL CAL Mode On Off cAL SEL Indicazione Metodo di calibrazione On Off Mode CAL Cl CAL RISULTATO x RISULTATO x Mode Zero Test 0 0 0 Zero Test R I S U L T A T O R I S U L T A T O CAL Zero ...

Страница 11: ...rdar 2 minutos por uma reacção colorida Pressione a tecla ZERO TEST O símbolo CA H piscará durante 3 segundos O resultado aparecerá no visor expresso em mg l CaCO3 Tolerância 5 em toda a escala Efectue a leitura do Zero Ver manuseamento Retire a célula do compartimento de teste adicione um comprimido ALKA M PHOTOMETER e esmague o até se dissolver por completo usando um triturador limpo Feche a cél...

Страница 12: ...itura Se houver suspeita de contaminação examine o visor 9 Quando usar reagentes em comprimidos use apenas comprimidos protegidos com folha metálica No caso dos comprimidos PHENOLRED devem estar marcados na folha metálica com PHOTOMETER 10 Os comprimidos devem ser adicionados à amostra de água sem serem tocados com os dedos 11 Elevadas diferenças de temperatura entre o fotómetro e o ambiente de tr...

Страница 13: ...n de display verschijnt het meetresultaat in mg l totaal chloor c gebonden Chloor gebonden chloor totaal chloor vrij chloor Toleranties 0 1 mg l 0 05 mg l 3 4 mg l 0 30 mg l 1 2 mg l 0 10 mg l 4 6 mg l 0 40 mg l 2 3 mg l 0 20 mg l Doe de nulstelling zie In bedrijf nemen Doe een PHENOLRED PHOTOMETER tablet direkt uit de folie in 10 ml monsterwater en maak deze fijn met een schone roerstaaf Tablet g...

Страница 14: ...igingen voorbehouden Printed in Germany 09 00 Druk op de MODE toets en houd deze ingedrukt Schakel de fotometer in met de ON OFF toets laat na ca 1 seconde de MODE toets los Druk voor het wisselen van het meetbereik de MODE toets CALCl CALpH CALCys CAL tA CALCA H Scroll Doe de normale nulstelling Druk de ZERO TEST toets Het methode symbool knippert ca 3 seconden In de aanwijzing verschijnt afwisse...

Страница 15: ...EST Metodesymbolet blinker i ca 3 sekunder Displayet viser resultatet i mg l klor total c bundet klor bundet klor klor total frit klor Tolerance 0 1 mg l 0 05 mg l 3 4 mg l 0 30 mg l 1 2 mg l 0 10 mg l 4 6 mg l 0 40 mg l 2 3 mg l 0 20 mg l Gennemfør nulkompensation se ibrugtagning En PHE NOLRED PHOTOMETER tablet tilsættes til 10 ml vandprøven direkte fra folien og knuses med en ren rørepind Opløs ...

Страница 16: ...tiveres fabrikations kalibreringen Displayet viser skiftevis Apparatet slukkes på tasten ON OFF Kalibrering out of range Cl Fabrikations kalibrering ukorrekt slettet pH Fabrikations kalibrering ukorrekt slettet Cys Fabrikations kalibrering ukorrekt slettet TA Fabrikations kalibrering ukorrekt slettet CAH Fabrikations kalibrering ukorrekt slettet Cl Bruger kalibrering ukorrekt slettet pH Bruger kal...

Отзывы: