-19-
Compatibility :
The sterilizer produced by your chlorinator is compatible with most swimming-pool
water treatment products, with the exception of those containing PHMB polymers. In
all cases, stop the chlorinator while you add products and until they have been com-
pletely dissolved.
INDICATORS
Flow switch fault :
When this indicator is lit all production is halted : this means that that the flow switch
is badly positioned, faulty or else the flow through the chamber is non-existent or insuf-
ficient.
Production fault :
When the electrode produces less than 75% of its capacity, the indicator lights up with-
out stopping the operation of the chlorinator :
- the salt content is insufficient
- the water temperature required the device to stop
- the electrode is encrusted with limescale (see paragraph on limescale
encrusted electrode)
- the electrode is weakening and should be replaced soon
(see paragraph about limescale encrusted electrode)
Stand-by :
The device has finished its production cycle according to the percentage that you have
indicated
using the + or - keys ; it is waiting for the end of the cycle (100%) so that it can re-start
on the other polarity.
Cover :
The indicator lights up when the cover is detected as closed. In order for this detec-
tion to be possible, please connect the dry contact on the card to the connector pro-
vided for this purpose when installing a cover.