![Astralpool 34624 Скачать руководство пользователя страница 16](http://html1.mh-extra.com/html/astralpool/34624/34624_manual_2990633016.webp)
-16-
CHECKS AND MAINTENANCE
CHECK THE PARAMETERS :
Press “MENU” for two seconds,
Scroll through the functions using + or -,
Then press “Menu” to visualise :
- DUR: duration of the polarity inversion (self-cleaning expressed in hours).
Factory setting : 3
- FE : regulates production according to the position of the cover.
Percentage of production depends on the cover being in the closed position.
Factory setting: 50%
- INT : intensity sent to the electrode (expressed in amperes).
- DEF :
settings, that is
- DUR :
3H
- FE :
50%
- PROD :
55%
- TPS :
accumulated production time
- TEN :
electrode operating voltage
UNCHANGEABLE PARAMETERS :
Device switched on :
- Press Menu once and DUR appears
(DUR = duration of polarity inversion)
- Press Menu: the screen displays 3 hours (factory setting)
- Press Menu to exit: the setting amperage appears
- Press Menu: DUR appears
- Press +: FE appears (FE = opening/closing of the cover)
- Press Menu: production time appears; 50% (factory setting 0.50)
- Press Menu to exit: the setting amperage appears
MODELS
AMPERAGE
40
5,5 amperes
60
8.5 amperes
100
12 amperes
160
14 amperes