700703 REV H 09/18
ADAEZ Wireless Interface Module
Installation and Operation Instructions
5 of 17
3. LEDs DS8 through DS11 shall flash GREEN.
2. Refer to Figure 3. PRESS and HOLD the LEARN
button and PRESS and RELEASE the RESET
button on the setup board.
NOTE:
1. Refer to Figure 2 and Remove the bottom cover
from the door operator to access the Setup board.
The ADAEZ swing door operator is shipped with
wireless RF pushbuttons that are pre-programmed to
the operator. The RF codes MUST be erased from the
ADAEZ swing door operator for proper operation.
7
Erase All RF Codes from the Door Operator
Figure 2
Figure 3
3. On the Setup board, LEDs DS8 through DS11
shall rapidly flash GREEN 3 times.
1. Refer to Figure 3 and PRESS and HOLD the
LEARN button until on the Operator Control
board until LEDs DS8-DS11 Flash Green.
2. Refer to Figure 4 and PRESS and RELEASE
the “OPERATOR SIGNAL” button on the WIM.
8
Learn WIM Module to Door Operator
9/64” HEX WRENCH
OPTION
OFF
OFF
ON
TUNING
POTENTIOMETER
1-4
ADJUSTMENT
INDICATOR LEDS
CLOSE
POSITION
OPEN
POSITION
AUTO
SETUP
LEARN
RESET
SELECT
ENTER
OPEN & CLOSE TIME
OPEN & PWR CLOSE
FORCE
HOLD OPEN/
EXECUTIVE
OPTIONS
PG
PC
LA
DB
4
3
2
1
OPTIONS:
POWER CLOSE
PUSH & GO
DYNAMIC BRAKING
LATCH ASSIST