700703 REV H 09/18
ADAEZ Wireless Interface Module
Installation and Operation Instructions
10 of 17
NOTE:
An optional Keyswitch or Access Control device may be
hard wired in series with the Outside Disable Button to
enable the Lock and Outside Pushbutton
2. Connect a Card Reader Access control OR Place a
Jumper across the ACCESS CTRL IN and COM.
NOTE:
Closing the OUTSIDE BUTTON DISABLE contact will
prevent the WIM from accepting an activation signal
from the OUTSIDE pushbutton. When the OUTSIDE
BUTTON DISABLE contact is closed the WIM will only
switch the lock state and activate the operator when an
INSIDE pushbutton signal is received.
1. Refer to Figure 6 and Connect the OUTSIDE
PUSHBUTTON DISABLE contact to the deadbolt
monitoring switch.
Placing a jumper across the ACCESS CTRL IN and
COM will maintain the lock in the UNLOCKED condition
unless the OUTSIDE BUTTON DISABLE contact is
CLOSED.
14
Connect the Outside Pushbutton Disable
LOCK
POWER
SUPPLY
FAIL SECURE
FAIL SAFE
Deadbolt
Status
Switch
Figure 8
Wired or Wireless
Pushbutton Connection
INSIDE
BUTTON
INSIDE BUTTON
PRESS & RELEASE
TO LEARN
HOLD TO ERASE
OUTSIDE
BUTTON
DOOR
OPERATOR
FIRE P
ANEL
IN COM OUT
A
CCESS CTR
OUTSIDE B
UTT
ON
DISABLE
LOCK
PO
WER
NO COM NC
LOCK
OUTSIDE BUTTON
PRESS & RELEASE
TO LEARN
HOLD TO ERASE
OPERATOR
SIGNAL
SIGNAL
DELAY
POWER IN
12 OR 24V
+
CH S
+
CH S
ACCESS
CONTROL
Connect to Access Control
OR
Jumper
Optional Keyswitch
Safety Override