Configuration
EN
Setting options on the escape door control terminal
Fig. 7 :
Switching elements
and connections
1 2 3 4 5
F2
F1
JP1
JP2
S4
S3
S2
S1
ON
OFF
AB
CDE
Jumpers (Tab. 1)
DIP switch S4 (Tab. 2)
Rotary switch S1 (Tab. 3)
Rotary switch S3 (Tab. 5)
Rotary switch S2 (Tab. 4)
Jumpers
Function
JP1
plugged
in at factory
Pre-alarm switched on: An acoustic pre-alarm is trig-
gered before an alarm. The pre-alarm does not affect
the alarm contact or the visual display.
open
Pre-alarm switched off: An acoustic pre-alarm is
suppressed. After the time set on rotary switch S2 has
elapsed, the alarm is triggered.
JP2
plugged
factory default
Permanent release switched on: Permanent release via the
key switch of the escape door control terminal is possible.
open
Permanent release switched off: Permanent release via
the key pushbutton is not possible.
Tab. 1
JP-1 and JP-2
(Fig. 7)