background image

 

 

WORK INSTRUCTION 

Work Instruction No. 

WI_AB_CXXXXXXXXX 

 

 

Step 12 

Installing the O-Ring and Rotating Half of the Mechanical Seal 

 

 
 
 
Install the o-ring onto the sealplate as shown in the picture. The o-ring should not be 
twisted or rolled. 
 
Place one side of the o-ring over the sealplate. With two fingers, stretch the o-ring over 
the other side while being careful not to roll the o-ring. 
 
Ensure the o-ring is flat against the flange of the sealplate. 

Step 13 (3 phase, 3HP and 5HP motors only!!!) 

Applying Thread Locking Compound to the Impeller Threads 

 

(3 phase, 3HP and 5HP motors only!!!) 

Apply a drop of thread locking compound to the impeller threads prior to installation. 
 

This process will help prevent the impeller from spinning off the shaft during a 
reverse rotation. 

 
When the impeller is screwed onto the motor shaft, the thread locking compound will 
screw into the threads along the entire shaft.

 

 

 

 

Содержание SSPC

Страница 1: ...Equipment Flexible Gloves to protect against cuts Safety Guidelines Equipment and Tools See Step 1 that describes the tools used Introduction This procedure describes the process for assembling a Mod...

Страница 2: ...WORK INSTRUCTION Work Instruction No WI_AB_CXXXXXXXXX 2 Exploded View Diagram of SSPC Pump Assembly...

Страница 3: ...or Single Phase motors shall skip this step If the motor is a 3 phase motor it has the capability of rotating in either direction In order to keep the impeller from spinning off the shaft during a sta...

Страница 4: ...o sit flat against the bottom of the seal seat Any tilt could lead to reduced seal life Dip the seal seat rubber into the pre prepared lubricating solution non abrasive dish soap water combo Be carefu...

Страница 5: ...or Component Installation and Remove Slinger Setup the motor on its rear end The motor shaft should be sticking up into the air Remove the rubber slinger from the motor If a slinger is not present col...

Страница 6: ...erified with a torque wrench Step 11 Install the Sealplate Locate the sealplate carefully over the shaft The seal should not touch the shaft during assembly This will prevent the seal face from chippi...

Страница 7: ...being careful not to roll the o ring Ensure the o ring is flat against the flange of the sealplate Step 13 3 phase 3HP and 5HP motors only Applying Thread Locking Compound to the Impeller Threads 3 p...

Страница 8: ...er needs to completely butt up against the shoulder of the shaft Failure to do so may result in damage to the impeller and the motor during startup Step 15 For 3 Phase motor Only Installing the thread...

Страница 9: ...apped far enough and the pump needs to be disassembled or a shorter locking screw may be used if in the field Step 17 Install the Drain Plug into the Case Using the 1 4 square socket by 3 8 Square soc...

Страница 10: ...the case flange and into the motor adapter plate Leave the bottom 2 screws out if using a stainless steel baseplate Check the BOM on the work order This can be seen in the picture on the right If usi...

Страница 11: ...irection and locking screw thread information shall be placed next to the discharge nozzle opposite the pump nameplate The labels shall be a minimum of from the discharge port radius and shall be para...

Страница 12: ...struction No WI_AB_CXXXXXXXXX 12 Step 23 Completed Assembly A completed pump assembly with a stainless steel baseplate can be seen in the picture on the left Date Revision Change 11 26 13 A Initial Re...