WORK INSTRUCTION
Work Instruction No.
WI_AB_CXXXXXXXXX
11
Step 20
Inspecting the Assembly for Proper Baseplate
If the motor is a footed motor, or an assembly with no base (catalog number ends
with L), skip this step.
Set the motor on its foot/base. Check the base to ensure the radius of the baseplate
matches the motor diameter. If not, contact the shop supervisor for further instruction.
The baseplate on the BOM may need to be changed.
Step 21
Label Placement
The pump nameplate shall be placed next to the discharge nozzle. The rotation arrow
shall be pointed in the clockwise direction, noting the proper rotating direction of the
motor shaft and impeller.
The label with thread direction and locking screw thread information shall be placed
next to the discharge nozzle, opposite the pump nameplate.
The labels shall be a minimum of ½” from the discharge port radius and shall be
parallel to the case flange. Crooked labels/nameplates are not acceptable.
Step 22
Inspecting the suction Nozzle for Location
The top of the suction nozzle must be level with the ground. If the suction nozzle
threads are crooked, it may not fit into the customers’ system if hard piped.
Place the pump onto the flat plate located next to the assembly bench. Zero out the
level on the same plate.
Place the level on top of the suction nozzle and verify the suction nozzle is within
tolerance. Acceptable levels are within ±1.1 degrees from flat.
If the level is not acceptable, either the motor register is off or the discharge nozzle is
not in the correct location. Contact QA immediately.