WORK INSTRUCTION
Work Instruction No.
WI_AB_CXXXXXXXXX
6
Step 9
Re-install Slinger
Place the slinger back over the shaft and press it against the adapter plate
Step 10
Install Adapter Plate Screws
Install the 4 motor mounting bolts by hand. This prevents the threads from galling or
breaking with installation using an air ratchet.
Tighten the motor bolts completely, using the air ratchet. The bolts should be
approximately 12 ft-lbs and can be verified with a torque wrench.
Step 11
Install the Sealplate
Locate the sealplate carefully over the shaft.
The seal should not touch the shaft during assembly. This will prevent the seal
face from chipping or becoming damaged.
When the sealplate is tight against the motor adapter plate, the motor shaft should not
be touching the stationary seal. Press the flanges of the sealplate and motor adapter
plate together with your hands for an approximate location.
The gap surrounding the shaft should be very close to concentric. If the gap does not
seem concentric, the motor adapter plate shall be inspected for proper tab height and
dimensions. See QA.