![Ashley AGVF340 Скачать руководство пользователя страница 9](http://html1.mh-extra.com/html/ashley/agvf340/agvf340_installation-and-operating-manual_2982347009.webp)
9
1. STOP! Read the safety information on reverse side of this label.
2. Make sure manual shutoff valve is fully closed. If equipped with thermostat, set to lowest setting.
3. Turn off all electrical power to appliance.
4. Open access door located at bottom of front of appliance.
5. Push in gas control knob slightly and turn clockwise to full “OFF” position.
NOTE: Knob cannot be turned from “PILOT” to “OFF” unless knob is pushed in slightly. Do not force.
6. Wait (5) five minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas,
STOP! Follow “B” in the safety information section of this manual. If you don’t smell gas, go to the next step.
7. Find Pilot: The pilot is located in front of rear log and burner on right hand side of appliance. Fully open
manual shutoff valve.
8. Press in and turn knob on gas control counterclockwise to “PILOT” and continue pressing in knob for (15)
fifteen seconds.
9. With control knob pressed in push down (in) and release ignitor button (ignitor button is located on front
left hand side of appliance). This will light pilot. If needed, keep repeating this step until pilot lights.
10. Keep control knob pressed in for (1) one minute after lighting pilot. After (1) minute, release control knob
and it will pop back up. Pilot should remain lit. If pilot goes out, repeat steps 1 through 9.
• If knob does not pop up when released, stop and immediately call your service technician or gas supplier.
• If pilot will not stay lit after several tries, turn the gas control knob to “OFF” and call your services technician
or gas supplier.
REMOTE CONTROL OR
WALL THERMOSTAT
LIGHTING INSTRUCTIONS