Limited Warranty

VENT-FREE HEATERS

United States Stove Company warrants to the original purchaser its products against premature failure of any component due to workmanship, quality, or 

materials as follows: 

TIME PERIOD:

Controls/Valves ........................................................................................... One Year From Time Of Purchase

Thermocouple/Thermopile ........................................................................... One Year From Time Of Purchase

All Electrical Components ............................................................................. One Year From Time Of Purchase

Combustion Chamber and Burner ................................................................Five Years From Time Of Purchase

CLAIM PROCEDURE

Any defects should be reported to United States Stove Company or its dealer and/or distributor giving descriptions and pertinent data, including proof or 

purchase which will be returned upon request.

Providing the heater has been installed and used in accordance with the Owners Manual supplied with the heater, United States Stove Company will either:

1)  Replace the defective part free of charge

2)  Replace the heater free of charge

3)  Where the defect is of a cosmetic (non-functional) nature, United States Stove Company will bear reasonable expense to refurbish the heater, includ-

ing such items as welding, painting, and incidental labor. A “Reasonable” is de  ned by terms of this warranty as $30.00/hour with full refund for any 

purchase of parts.

NOT COVERED

Speci  cally not covered under terms of this limited warranty or any other warranty are problems relating to smoking or creosote.  Smoking is attributable 

to inadequate draft due to the design or installation of the   ue system or installation of the heater itself.  Creosote formation is largely attributable to 

improper operation of the unit and/or draft as mentioned above.  Also, not covered are:

1)  Removal and re-installation cost.

2)  Service calls to diagnose trouble (unless authorized in writing by the manufacturer, distributor, or dealer).

3)  Damage or defect caused by improper installation, accidents, misuse, abuse (including over  ring) or alteration.

4)  Transportation or shipping costs.

LIMITATIONS AND EXCLUSIONS

1)  United States Stove Company shall not be liable for incidental, consequential, special, or contingent damages anyone might suffer as a result of their 

breach of this written warranty or any implied warranty.

2)  Should the heater be replaced by United States Stove Company “free of charge”, all further warranty obligations are thereby met.

3)  Parts and/or service replacements made under the terms of this warranty are warranted only for the remaining period of the original heater warranty.

4)  Without speci  c written exclusionary waivers, no one has authority to add to or vary this limited warranty, or to create for United States Stove Com-

pany any further obligation of liability in connection with this heater or any other applicable accessory.  Any further warranty implication applicable to 

this heater or any applicable accessory is limited in duration to the same time period as the original statement in the above schedule.

YOUR DUTIES

1)  This heater, including all applicable accessories, must be installed and operated in accordance with local authorities having jurisdiction and the instruc-

tions furnished with the Owners Manual.

2)  You should keep as permanent record your proof of purchase (or canceled check or invoice).

PROBLEM/RESOLUTION

1)  As purchaser, you must   rst contact the dealer and/or distributor from whom you purchased your heater.

2)  If within a reasonable period of time you do not receive satisfactory service from the distributor and/or dealer, write or call United States Stove Com-

pany, Customer Service Department, including complete details of the problem and/or problems you are experiencing, details of your installation, your 

proof of purchase, and the heater serial number or test agency code number.

WARRANTOR

The warrantor of record is United States Stove Company, PO Box 151, 227 Industrial Drive, South Pittsburg, Tennessee 37380.

Phone number: 800-750-2723.

NOTE

This warranty gives you speci  c legal rights; and, you may also have other rights which vary from state to state.

Содержание AGVF340

Страница 1: ...erating Manual AGVF340 Certified for installations in the USA Approved for installation in mobile homes Do not store or use gasoline or other flammable vapors and liquids in vicinity of this or any ot...

Страница 2: ...or propane LP and one for natural gas Use the correct type gas for your home Do not convert from one gas type to another 4 If this heater is used with propane gas do not place propane supply tank s in...

Страница 3: ...tc It is imperative that control compartments burners and circulating air passageways of appliance be kept clean 20 All heater screens must be kept closed when operating gas logs 21 WARNING Failure to...

Страница 4: ...DOORS SCREEN RAILS SCREEN MESH AND SOLID FUEL LOG GRATES IF APPLICABLE CAN BE REMOVED FROM FIREPLACE BEFORE INSTALLING UNVENTED FIREPLACE INSERT WARNING BEFORE INSTALLING IN A SOLID FUEL BURNING FIREP...

Страница 5: ...wing sections for installation options Section III Installation In A Solid Fuel Burning Fireplace and Section IV Installation With Optional Wooden Mantel and Section V Zero Clearance Installation Norm...

Страница 6: ...on pins located on left top section of Middle log 2 4 Place Right Top Middle log 4 on pin located on right top section of Middle log 2 and align notch on right side 4 with side shield on right 5 Place...

Страница 7: ...r the purpose of minimum input adjustment Solid fuels shall not be burned in the same fireplace where an unvented room heater has been installed NOTE The following label has been provided with this ap...

Страница 8: ...ea for gas Be sure to smell next to floor because some gas is heavier than air and will settle to floor WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electric switch d...

Страница 9: ...r log and burner on right hand side of appliance Fully open manual shutoff valve 8 Press in and turn knob on gas control counterclockwise to PILOT and continue pressing in knob for 15 fifteen seconds...

Страница 10: ...OFF 4 Turn off all electric power to appliance if service is to be performed 5 Close access cover door SHUTTING OFF BURNER ONLY Pilot stays lit Turn control knob clockwise to PILOT position CAUTION H...

Страница 11: ...g should be very similar yellow in color and should be about 3 to 4 above large rear log for natural gas logs and about 6 for propane LP gas log sets Front Flame The flame should be 1 1 2 to 2 high an...

Страница 12: ...ted before use and at least annually by a qualified service person More frequent cleaning may be required due to excessive lint from carpeting bedding material etc It is imperative that control compar...

Страница 13: ...e or listed ventless enclosure in which unvented fireplace is to be installed is prohibited NOTE If factory built fireplace has no gas access hole s provided an access hole of 1 5 inch 37 5 diameter o...

Страница 14: ...AL KITS There are optional kits available for your stove These are listed below Insert Fireplace Facade Wooden Surround Brick Panel Kit Stainless Steel Kit For more information on these kits contact y...

Страница 15: ...attern in your room and location of doors and windows Moving air from ceiling fans open doors and hot air grills may cause flames to soot If a disturbance is found that affects flames it must be elimi...

Страница 16: ...E If installing with the mantle kit refer to the instructions included with the mantle kit for correct installation Back Standoff located 7 from the top of the rear of the appliance and center left to...

Страница 17: ...ding a small platform to achieve desired height NOTE Wiring for lower blower must be installed during framing stage Insulation should be used in framing on back sides and top INSTALL FIREBOX Install f...

Страница 18: ...tain combustible materials Combustible wall coverings such as paneling or wall board may not overlap black face of fireplace Space between wall covering and fireplace should be sealed with a heat resi...

Страница 19: ...nce is not convertible for use with other gases WARNING YOUNG CHILDREN SHOULD BE CAREFULLY SUPERVISED WHEN THEY ARE IN SAME ROOM WITH APPLIANCE CHILDREN AND ADULTS SHOULD BE ALERTED TO HAZARDS OF HIGH...

Страница 20: ...EFORE INSTALLING HEATER 1 For clearances see Figure below The minimum must be met 2 For Installation and Gas Hookup Connection see Gas Connection section of this manual CAUTION The installation must c...

Страница 21: ...less with openings gasketed or sealed B Weather stripping has been added on openable windows and doors C Caulking or sealants are applied to areas such as joints around window and door frames between...

Страница 22: ...18000BTU Hr total 58000 BTU Hr Does not include direct vent gas appliances Direct vent draws combustion air from outdoors and vents to the outdoors 4 Compare the maximum BTU Hr the space can support w...

Страница 23: ...SPACE OF ADJOINING UNCONFINED SPACE COMBINED SPACES MUST HAVE ADEQUATE AMOUNT OF AIR TO SUPPLY ALL APPLIANCES IN BOTH SPACES NOTE Each opening shall have a minimum free area of 1 square inch per 1000...

Страница 24: ...attics and crawl spaces Follow National Fuel Gas Code NFPA 54 ANSI Z223 1 Section 5 3 Air For Combustion and Ventilation for required size of ventilation grills or ducts IMPORTANT Do not provide openi...

Страница 25: ...SE OR DELIBERATELY FRAGMENTING MATERIAL COULD LEAD TO INHALING FIBERS AND BE HAZARDOUS TO YOUR HEALTH THIS HEATER IS INTENDED FOR USE AS A GAS HEATER FIREPLACE AS DESCRIBED IN THESE INSTRUCTIONS IT SH...

Страница 26: ...the side wall horizontally vented gas fueled equipment is installed in a crawl space or an attic the hard wired carbon monoxide detector with alarm and battery back up may be installed on the next ad...

Страница 27: ...zontally vented gas fueled equipment does not provide the parts for venting the flue gases but identifies special venting systems the following requirements shall be satisfied by the manufacturer The...

Страница 28: ...r nut is loose Tighten nut holding piezo igniter to heater cabinet Nut is located inside heater cabinet at top Broken igniter cable Replace igniter cable Bad piezo igniter Replace piezo igniter Ignite...

Страница 29: ...ODS Pilot is lit Burner orifice is clogged Clean burner see Cleaning and Maintenance or replace burner orifice Inlet gas pressure is too low Contact local propane gas company Delayed ignition of burn...

Страница 30: ...is available Open window door for ventilation Low line pressure Contact local propane co ODS Pilot is partially clogged Clean ODS Pilot Gas odor even when control knob is in OFF position Gas leak See...

Страница 31: ...31 SIT MILLIVOLT VALVE BASE 8 10 12 3 1 2 6 5 7 4 9 11...

Страница 32: ...gnitor 1 3 81196 Control Valve LP 1 81198 Control Valve NAT 1 4 81212 6 Bottom Burner 1 5 81212 8 On Off Valve 1 6 81212 14 Auto Off Auto Switch 1 7 89921 Pilot Assembly NAT 1 89922 Pilot Assembly LP...

Страница 33: ...__________ Company ________________________________________ Telephone No ______________________________________ Stove Inspected Chimney Swept Items Replaced ____________________________________ Servic...

Страница 34: ...4 Transportation or shipping costs LIMITATIONS AND EXCLUSIONS 1 United States Stove Company shall not be liable for incidental consequential special or contingent damages anyone might suffer as a res...

Страница 35: ...35 NOTES...

Страница 36: ...GIVE THE FULL MODEL NUMBER WHICH IS ON THE NAMEPLATE ATTACHED TO THE HEATER WHEN ORDERING REPAIR PARTS ALWAYS GIVE THE FOLLOWING INFORMATION AS SHOWN IN THIS LIST 1 THE PART NUMBER 2 THE PART DESCRIP...

Отзывы: