OBSERVED
PROBLEM POSSIBLE CAUSE
SOLUTION
Igniter button is pressed no spark
at ODS/Pilot
Igniter electrode positioned
incorrectly
Replace igniter
Igniter electrode broken
Replace igniter
Igniter electrode not connected to
igniter cable
Reconnect igniter cable
Igniter cable pinched or wet
Free igniter cable if pinched by
any metal or tubing. Keep igniter
cable dry
Piezo igniter nut is loose
Tighten nut holding piezo igniter
to heater cabinet. Nut is located
inside heater cabinet at top
Broken igniter cable
Replace igniter cable
Bad piezo igniter
Replace piezo igniter
Igniter button is pressed Spark at
ODS/Pilot No Ignition
Gas supply turned off or
manual shutoff valve is closed
Turn on gas supply or open
manual shutoff valve
Control knob not in “PILOT”
position
Turn control knob to “PILOT”
position
Control knob not pressed in while
in “PILOT” position
Press in control knob while in
“PILOT” position
Air in gas lines when installed
Continue to hold down control
knob. Repeat igniting operation
until air is removed.
Depleted gas supply
Contact local propane gas
company
ODS/Pilot is clogged
Clean ODS/Pilot or replace ODS/
Pilot assembly
Gas regulator setting is not correct
Replace gas regulator