Follow the Steps below to customize the

AEU-27A default Series:

1.

Use the SERIES Left/Right arrow buttons to

select the specific Series (S1-S5) you wish

to customize. 

2.

Press and hold the EDIT button. Two beeps

will sound and then the following Series

Options Menu will display:

3.

Using the FILE Up/Down buttons, move the

selector-arrow to the desired option and

then press the SELECT button. Prompts

will appear for each option - see

descriptions below and on pages 21-24.

Note:

The Cancel option will return the

user to the last-used Series settings without

saving any changes. 

A. Save Current Settings:
1)

Once the “Series Options” Menu is

displayed above in Step-2, position the

selector-arrow at the “Save Current Set-

tings” option and press the SELECT button.

The following “USER DEFINED FILE

NAME” Menu will display (Example Only):

A flashing cursor will appear under the first

letter in “USER DEFINED FILE NAME”, and

the following three commands will scroll

across the bottom of the menu, which allow

the user to edit the file name, adjust the

speed and torque, and save any changes:

a) Edit File Name With Arrows:

If you

wish to save your new settings under a

new FILE name, use the Left/Right SERIES

Arrow buttons to move the flashing cursor

laterally under a specific letter in the name,

then press the FILE Up/Down Arrow

buttons to select the desired alphanumeric

symbol. (The Down Arrow moves forward

through the alphanumeric range; the Up

Arrow moves backward.)

b) Press Speed Or Torque Buttons To

Change:

This prompt gives the user one

more opportunity to change the Speed and

Torque settings before saving them under

the new FILE name. Press the Speed or

Torque Up/Down buttons as desired. 

Note:

These final changes will overwrite any

previous Speed or Torque edits.

c) SELECT To Save:

After you have edited

the File Name and adjusted the Speed and

Torque settings in the steps above, you can

save your new settings by pressing the

SELECT button. The following Menu will

appear:

Move the selector-arrow to the desired

command using the FILE Up/Down Arrow

buttons and then press the SELECT button: 

• YES

- Saves the customized changes into

the SERIES location, overwriting the

previous settings. 

• No

- Returns to the previous SERIES

menu without saving any edits or changes.

• Cancel 

- Returns to the previous File Edit

menu without saving any edits or changes.

Series Options:

> Save Current Settings

Load From Library

Modify Series

Cancel

USER DEFINED FILE NAME

1800 RPM

30 g-cm

Edit File Name With Arrows.

Save Series Changes?

> Yes

No

Cancel

ADVANCED OPERATION - 

Editing and Creating Series:

Содержание AEU-27A

Страница 1: ...AEU 27A Electronic Endodontic System OPERATION AND MAINTENANCE INSTRUCTION MANUAL...

Страница 2: ...E OF CONTENTS Introduction 1 Package Contents 1 Indications for Use 2 Contraindications 2 Adverse Reactions 2 Warnings Safety Precautions 2 Step By Step Instructions 4 Setting Up the Unit 4 Quick Star...

Страница 3: ...may be provided to cover the operation and maintenance of handpieces or other accessories for your unit PACKAGE CONTENTS AEU 27A Electronic Control Console Autoclavable Brushless Micromotor P N AE 25...

Страница 4: ...rty manufacturers is the sole responsibility of the user CAUTION All repairs are to be performed by authorized Aseptico service personnel only WARNING Always follow these guidelines when operating the...

Страница 5: ...only WARNING Do not disassemble or alter the AE 250 30 micromotor console or foot switch CAUTION Use only appliance cord Type C13 10A per IEC EN 60320 1 Note North America Denmark Australia and New Ze...

Страница 6: ...Figure 3 The cord connector and receptacle are keyed to engage one another Insert then turn the locking nut clockwise to secure 4 Attach the remote power cord to the back of the console see Figure 3 a...

Страница 7: ...appropriate E Type handpiece to the motor as shown in Figure 4 Fig 3 Console Back POWER CORD IN MAIN POWER ON OFF SWITCH MEMORY CARD PORT FOOT SWITCH IN FUSES E TYPE HANDPIECE MOTOR Fig 4 Handpiece Mo...

Страница 8: ...eduction 4 Use the Calibration function to calibrate the handpiece for the AEU 27A Before calibrating ensure that the correct handpiece ratio is selected Press and release the CAL button The following...

Страница 9: ...each Series name These Up Down Arrow buttons can also be used to navigate up or down through the menu options 6 Press the foot pedal to activate motor and begin operation Note that the word RUN displa...

Страница 10: ...rsal S1 SX File 2 ProTaper Universal S2 F1 File 3 ProTaper Universal F2 F3 F4 F5 File 4 ProTaper Universal Retreatment D1 D2 File 5 ProTaper Universal Retreatment D3 Default Series 4 DENTSPLY Tulsa De...

Страница 11: ...CONTROL PANEL FUNCTIONS MOTOR RECEPTACLE LIQUID CRYSTAL DISPLAY CALIBRATION SYSTEM SETUP RECALL FACTORY SETUP AUTO STOP REVERSE REVERSE BEEPER TORQUE WARNING ACCESSORY WARN SLEEP MODE KEYPRESS BEEP S...

Страница 12: ...on on changing these settings B Press and hold the RATIO button to display a list of all the handpiece ratio options Then use the FILE Up Down arrow buttons to point to the desired option and press th...

Страница 13: ...speed accuracy the Ratio Selector must match the ratio of the handpiece being used Note Speed ranges are accurate when the handpieces referenced on page 1 are used with the supplied 30K motor Speed r...

Страница 14: ...allows the motor to run at its maximum torque level When the MAX function is enabled the Auto Stop Reverse ASR function and the torque warning tone are automatically disabled IMPORTANT When a 1 5 han...

Страница 15: ...13...

Страница 16: ...h the system s keypad functions use either 1 Manual Mode or 2 Series Mode below to begin operation 1 MANUAL MODE At any time the user can use the control panel keypad to adjust the ratio speed torque...

Страница 17: ...write the current settings in the selected Series To restore the default Series settings to this Series either re enter the previous settings manually or Recall the Factory Setup see page 16 No Return...

Страница 18: ...nd are not saved into any specific Series when programming B Auto Stop Rev Reverse There are three different Auto Stop modes to choose from After pressing the SELECT button the following menu will dis...

Страница 19: ...enu Cancel Exits out of the menu and returns to the Setup Options menu without saving any setup changes D Torque Warning When the Torque Warning feature is active ON a chirping sound will be audible w...

Страница 20: ...utes of inactivity Sleep Mode 30 will be displayed on the Setup Options menu Cancel Exits out of the Sleep Mode menu and returns to the Setup Options menu without saving any changes G Keypress Beep Wh...

Страница 21: ...e changed then saved altogether at one time This Save Settings option requires the user to either save or ignore the new Setup settings or to cancel out of the menu When this option is selected the fo...

Страница 22: ...t SERIES Arrow buttons to move the flashing cursor laterally under a specific letter in the name then press the FILE Up Down Arrow buttons to select the desired alphanumeric symbol The Down Arrow move...

Страница 23: ...ries Loads the entire file series into the SERIES location Load Individual File Displays a sub menu listing of all the available individual files in the selected SERIES Move the FILE Up Down selector...

Страница 24: ...Returns to the previous Modify Series menu without saving any changes Edit When Select button is pressed the following menu will display example Only A flashing cursor will appear under the first lett...

Страница 25: ...Series menu Move Down When the Select button is pressed the File is immediately moved down one position in the individual file list in the Modify Series menu c End Of Series When the End Of Series opt...

Страница 26: ...wn Arrow buttons to select the desired alphanumeric symbol SELECT To Save Edits After you have edited the Series Name you can Save your new Series by pressing the SELECT button The following Menu will...

Страница 27: ...Turn the Main Power Switch on the back panel On 5 The AEU 27A Display will show the following message Press the RATIO key on the Control Panel 6 The Display will show the following message Press the...

Страница 28: ...per operation and service life of the handpiece Follow the instructions provided with the hand piece for complete maintenance instructions IMPORTANT Protect motor from excess oil draining from handpie...

Страница 29: ...f the console may be cleaned by wiping with a soft cloth moistened with a mild detergent or a 1 10 bleach solution 1 part household bleach to 10 parts water IMPORTANT Use of other cleaning or disinfec...

Страница 30: ...tion Check foot pedal connection Depress foot pedal Increase RPM Increase Torque setting Check that a file is properly seated in the handpiece and the latch is closed Check for dirty under lubricated...

Страница 31: ...nlet is the mains disconnect means Environmental Conditions Operating Temperature 10 to 28 C 50 to 82 4 F Transportation Storage Temperature 20 to 60 C 4 to 140 F Relative Humidity 10 to 90 non conden...

Страница 32: ...s in the Fuse holder Replacement Fuses 1 6A 250V slo blow fuse Fuse size 5 x 20mm Turn the power off and unplug the unit before following the steps below WARNING Fig 10 Fuses NOTE The AEU 27A features...

Страница 33: ...zed European Representative Protection Against Dripping Water Protective Earth Ground 250V Temperature Limitation Atmospheric Pressure Limitation Humidity Limitation Attention consult accompanying doc...

Страница 34: ...32 NOTES...

Страница 35: ...ter of such action In the event of alleged defect under warranty the purchaser is to notify Aseptico s Customer Service Department promptly Customer Service will provide instructions usually directing...

Страница 36: ...P N 421029 Rev C ECO 14684 03 2019 PRINTED IN THE USA P O Box 1548 Woodinville WA 98072 8333 216th Street S E Woodinville WA 98072 425 487 3157 800 426 5913 www aseptico com info aseptico com...