Engineering & Physical Data
ACK-E-2009
General Data - Heat Pump (R410A)
MODEL
INDOOR UNIT
A5CK 40ER
A5CK 40ER
OUTDOOR UNIT
A5LC 35CR
A5LC 40CR
NOMINAL COOLING CAPACITY - 1Ø / <3Ø>
Btu/h
29200 / <31000>
39000 / <39000>
W
8558 / <9086>
11430 / <11430>
NOMINAL HEATING CAPACITY - 1Ø / <3Ø>
Btu/h
31800 / <33400>
39000 / <39500>
W
9320 / <9789>
11430 / <11577>
NOMINAL TOTAL INPUT POWER (COOLING) - 1Ø / <3Ø>
W
2820 / <2770>
3920/ <3840>
NOMINAL TOTAL INPUT POWER (HEATING) - 1Ø / <3Ø>
W
2550 / <2550>
3740 / <3610>
NOMINAL RUNNING CURRENT (COOLING) - 1Ø / <3Ø>
A
13.6 / <5.2>
17.8 / <6.9>
NOMINAL RUNNING CURRENT (HEATING) - 1Ø / <3Ø>
A
12.7 / <5.0>
17.2 / <6.6>
POWER SOURCE - 1Ø <3Ø>
V/Ph/Hz
220 - 240 / 1 / 50 /
<380 - 415 / 3 / 50>
220 - 240 / 1 / 50 /
<380 - 415 / 3 / 50>
EER - 1Ø / <3Ø>
W/W
3.03 / <3.28>
2.92 / <2.98>
COP - 1Ø / <3Ø>
W/W
3.66 / <3.84>
3.06 / <3.21>
REFRIGERANT TYPE
R410A
R410A
REFRIGERANT CONTROL (EXPANSION DEVICE)
OUTDOOR CAP. TUBE
OUTDOOR CAP. TUBE
INDOOR UNIT
CONTROL
AIR DISCHARGE
4 WAY AUTOMATIC LOUVER
(UP & DOWN)
4 WAY AUTOMATIC LOUVER
(UP & DOWN)
OPERATION
WIRELESS OR WIRED MICRO-
COMPUTER REMOTE CONTROL
WIRELESS OR WIRED MICRO-
COMPUTER REMOTE CONTROL
AIR FLOW
HIGH
l/s / CFM
490 / 1030
490 / 1030
MEDIUM
l/s / CFM
410 / 860
410 / 860
LOW
l/s / CFM
350 / 740
350 / 740
EXTERNAL STATIC PRESSURE (H/M/L)
Pa (in.wg.)
0
0
SOUND PRESSURE LEVEL (H/M/L)
dBA
44 / 41 / 38
44 / 41 / 38
UNIT DIMENSION
( ) - WITH PANEL
HEIGHT
mm/in
300 (375) / 11.81 (14.76)
300 (375) / 11.81 (14.76)
WIDTH
mm/in
820 (990) / 32.3 (38.98)
820 (990) / 32.3 (38.98)
DEPTH
mm/in
820(990) / 32.3 (38.98)
820(990) / 32.3 (38.98)
PACKING DIMENSION
( ) - PANEL
HEIGHT
mm/in
335 (110) / 13.19 (4.3)
335 (110) / 13.19 (4.3)
WIDTH
mm/in
916 (1030) / 36.1 (40.6)
916 (1030) / 36.1 (40.6)
DEPTH
mm/in
916 (1030) / 36.1 (40.6)
916 (1030) / 36.1 (40.6)
WEIGHT (UNIT + PANEL)
kg/lb
42+6 / 92.6+13.2
42+6 / 92.6+13.2
CONDENSATE DRAIN SIZE
mm/in
19.1 / 0.75
19.1 / 0.75
OUTDOOR UNIT
AIR FLOW
l/s / CFM
1605 / 3400
1605 / 3400
SOUND PRESSURE LEVEL
dBA
58
58
UNIT DIMENSION
HEIGHT
mm/in
850 / 33.5
850 / 33.5
WIDTH
mm/in
1030 / 40.6
1030 / 40.6
DEPTH
mm/in
400 / 15.8
400 / 15.8
PACKING DIMENSION
HEIGHT
mm/in
1000 / 39.4
1000 / 39.4
WIDTH
mm/in
1200 / 47.2
1200 / 47.2
DEPTH
mm/in
560 / 22.1
560 / 22.1
UNIT WEIGHT
kg/lb
95 / 209
100 / 221
PIPE CONNECTION
TYPE
FLARE VALVE
FLARE VALVE
SIZE
LIQUID
mm/in
9.51 / 3/8
9.5 / 3/8
GAS
mm/in
15.9 / 5/8
15.9 / 5/8
REFRIGERANT CHARGE
kg/lb
2.175 / 4.80 / <2.15 / 4.74>
2.45 / 5.40 / <2.425 / 4.35>
1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.
2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO 5151.
3) NOMINAL COOLING AND HEATING CAPACITY ARE BASED ON THE CONDITIONS BELOW :
a) COOLING - 27°C DB / 19°C WB INDOOR AND 35°C DB / 24°C WB OUTDOOR
b) HEATING - 20°C DB INDOOR AND 7°C DB / 6°C WB OUTDOOR
4) SOUND PRESSURE LEVEL ARE ACCORDING TO JIS C 8615 STANDARD. POSITION OF THE MEASUREMENT POINT IS 1.5m BELOW FASCIA.
07-General data_A.indd 51
07-General data_A.indd 51
4/6/2009 11:13:11 AM
4/6/2009 11:13:11 AM
Содержание A5CK 20E
Страница 115: ...113 Wiring Diagram ACK E 2009 08024 105059 Indoor Unit Outdoor Unit Model ACK A5CK 40E Model ALC A5LC 35 40C 1 Phase...
Страница 116: ...114 ACK E 2009 Wiring Diagram 08024 105061 Indoor Unit Outdoor Unit Model ACK A5CK 40 50E Model ALC A5LC 40 50C 3 Phase...
Страница 118: ...116 ACK E 2009 Wiring Diagram 08024 105063 Indoor Unit Outdoor Unit Model ACK 40ER Model ALC 35 40CR 1 Phase...
Страница 119: ...117 Wiring Diagram ACK E 2009 08024 105064 Indoor Unit Outdoor Unit Model ACK 40 50ER Model ALC 35 40CR 3 Phase ALC 50CR...
Страница 120: ...118 ACK E 2009 Wiring Diagram 08024 105065 Indoor Unit Outdoor Unit Model A5CK 40ER Model A5LC 35CR 1 Phase...
Страница 121: ...119 Wiring Diagram ACK E 2009 08024 105066 Indoor Unit Outdoor Unit Model A5CK 40ER Model A5LC 40CR 1 Phase...