28
ACK-E-2009
Application Information
(6) Additional Charge
The refrigerant charge has already charged into the outdoor unit. For the piping length of 7.6m, additional
refrigerant charge after vacuuming is not necessary.
When the piping length is more than 7.6m, please use the table below (unit in gram).
R22
Model
10m
12m
15m
25m
35m
45m
20C/CR
38 / 53
70 / 96
118 / 162
-
-
-
25C/CR
94 / 53
172 / 98
289 / 164
-
-
-
28C/CR
94 / 133
172 / 244
291 / 411
-
-
-
30C/CR
133 / 133
244 / 243
410 / 409
964 / 961
1518 / 1514
2072 / 2067
35C/CR
130 / 136
238 / 248
400 / 418
940 / 983
1481 / 1547
2021 / 2112
40C/CR
134 / 136
245 / 248
412 / 418
968 / 983
1525 / 1547
2081 / 2112
50C/CR
130 / 134
238 / 245
400 / 412
942 / 968
1483 / 1525
2024 / 2081
R410A
Model
10m
15m
20m
25m
35m
45m
20C/CR
24 / 40
44 / 73
74 / 123
-
-
-
25C/CR
24 / 23
45 / 43
75 / 72
-
-
-
28C/CR
58 / 91
106 / 167
178 / 281
-
-
-
35C/CR
65 / 98
118 / 180
199 / 303
469 / 712
738 / 1122
1007 / 1531
40C/CR
61 / 97
112 / 178
189 / 299
445 / 703
700 / 1107
956 / 1511
50C/CR
50 / 87
92 / 159
155 / 267
363 / 628
572 / 989
781 / 1350
•
•
05_Application Information_A.ind28 28
05_Application Information_A.ind28 28
4/6/2009 3:32:58 PM
4/6/2009 3:32:58 PM
Содержание A5CK 20E
Страница 115: ...113 Wiring Diagram ACK E 2009 08024 105059 Indoor Unit Outdoor Unit Model ACK A5CK 40E Model ALC A5LC 35 40C 1 Phase...
Страница 116: ...114 ACK E 2009 Wiring Diagram 08024 105061 Indoor Unit Outdoor Unit Model ACK A5CK 40 50E Model ALC A5LC 40 50C 3 Phase...
Страница 118: ...116 ACK E 2009 Wiring Diagram 08024 105063 Indoor Unit Outdoor Unit Model ACK 40ER Model ALC 35 40CR 1 Phase...
Страница 119: ...117 Wiring Diagram ACK E 2009 08024 105064 Indoor Unit Outdoor Unit Model ACK 40 50ER Model ALC 35 40CR 3 Phase ALC 50CR...
Страница 120: ...118 ACK E 2009 Wiring Diagram 08024 105065 Indoor Unit Outdoor Unit Model A5CK 40ER Model A5LC 35CR 1 Phase...
Страница 121: ...119 Wiring Diagram ACK E 2009 08024 105066 Indoor Unit Outdoor Unit Model A5CK 40ER Model A5LC 40CR 1 Phase...