37
Engineering & Physical Data
ACK-E-2009
Engineering & Physical Data
General Data - Cooling Only (R22)
MODEL
INDOOR UNIT
ACK 20E
ACK 25E
OUTDOOR UNIT
ALC 20C
ALC 25C
NOMINAL CAPACITY
Btu/h
19500
25000
W
5715
7327
NOMINAL TOTAL INPUT POWER
W
1960
2540
NOMINAL RUNNING CURRENT
A
8.8
11.5
POWER SOURCE
V/Ph/Hz
220 - 240 / 1 / 50
220 - 240 / 1 / 50
EER
W/W
2.91
2.89
REFRIGERANT TYPE
R22
R22
REFRIGERANT CONTROL (EXPANSION DEVICE)
OUTDOOR CAP. TUBE
OUTDOOR CAP. TUBE
INDOOR UNIT
CONTROL
AIR DISCHARGE
4 WAY AUTOMATIC LOUVER
(UP & DOWN)
4 WAY AUTOMATIC LOUVER
(UP & DOWN)
OPERATION
WIRELESS OR WIRED MICRO-
COMPUTER REMOTE CONTROL
WIRELESS OR WIRED MICRO-
COMPUTER REMOTE CONTROL
AIR FLOW
HIGH
l/s / CFM
280 / 600
320 / 680
MEDIUM
l/s / CFM
250 / 530
280 / 600
LOW
l/s / CFM
200 / 430
250 / 530
EXTERNAL STATIC PRESSURE (H/M/L)
Pa / in.wg.
0
0
SOUND PRESSURE LEVEL (H/M/L)
dBA
34 / 31 / 28
37 / 34 / 31
UNIT DIMENSION
( ) - WITH PANEL
HEIGHT
mm/in
265 (340) /10.43 (13.39)
265 (340) / 10.43 (13.39)
WIDTH
mm/in
820 (990) / 32.3 (38.98)
820 (990) / 32.3 (38.98)
DEPTH
mm/in
820 (990) / 32.3 (38.98)
820 (990) / 32.3 (38.98)
PACKING DIMENSION
( ) - PANEL
HEIGHT
mm/in
300 (110) / 11.8 (4.33)
300 (110) / 11.8 (4.33)
WIDTH
mm/in
916 (1030) / 36.1 (40.6)
916 (1030) / 36.1 (40.6)
DEPTH
mm/in
916 (1030) / 36.1 (40.6)
916 (1030) / 36.1 (40.6)
UNIT WEIGHT (UNIT + PANEL)
kg/lb
29+6 / 63.9+13.2
29+6 / 63.9+13.2
CONDENSATE DRAIN SIZE
mm/in
19.1 / 0.75
19.1 / 0.75
OUTDOOR UNIT
AIR FLOW
l/s / CFM
614 / 1300
755 / 1600
SOUND PRESSURE LEVEL
dBA
51
52
UNIT DIMENSION
HEIGHT
mm/in
654 / 25.7
756 / 29.8
WIDTH
mm/in
855 / 33.7
855 / 33.7
DEPTH
mm/in
328 / 12.9
328 / 12.9
PACKING DIMENSION
HEIGHT
mm/in
710 / 28.0
810 / 31.9
WIDTH
mm/in
990 / 39.0
990 / 39.0
DEPTH
mm/in
415 / 16.3
415 / 16.3
UNIT WEIGHT
kg/lb
59 / 130
62 / 137
PIPE CONNECTION
TYPE
FLARE VALVE
FLARE VALVE
SIZE
LIQUID
mm/in
6.4 / 1/4
9.5 / 3/8
GAS
mm/in
15.9 / 5/8
15.9 / 5/8
REFRIGERANT CHARGE
kg/lb
1 / 2.20
1.25 / 2.76
1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.
2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO 5151.
3) NOMINAL COOLING AND HEATING CAPACITY ARE BASED ON THE CONDITIONS BELOW :
COOLING - 27°C DB / 19°C WB INDOOR AND 35°C DB / 24°C WB OUTDOOR
4) SOUND PRESSURE LEVEL ARE ACCORDING TO JIS C 9612 STANDARD. POSITION OF THE MEASUREMENT POINT IS 1.4m BELOW FASCIA.
07-General data_A.indd 37
07-General data_A.indd 37
4/6/2009 11:13:03 AM
4/6/2009 11:13:03 AM
Содержание A5CK 20E
Страница 115: ...113 Wiring Diagram ACK E 2009 08024 105059 Indoor Unit Outdoor Unit Model ACK A5CK 40E Model ALC A5LC 35 40C 1 Phase...
Страница 116: ...114 ACK E 2009 Wiring Diagram 08024 105061 Indoor Unit Outdoor Unit Model ACK A5CK 40 50E Model ALC A5LC 40 50C 3 Phase...
Страница 118: ...116 ACK E 2009 Wiring Diagram 08024 105063 Indoor Unit Outdoor Unit Model ACK 40ER Model ALC 35 40CR 1 Phase...
Страница 119: ...117 Wiring Diagram ACK E 2009 08024 105064 Indoor Unit Outdoor Unit Model ACK 40 50ER Model ALC 35 40CR 3 Phase ALC 50CR...
Страница 120: ...118 ACK E 2009 Wiring Diagram 08024 105065 Indoor Unit Outdoor Unit Model A5CK 40ER Model A5LC 35CR 1 Phase...
Страница 121: ...119 Wiring Diagram ACK E 2009 08024 105066 Indoor Unit Outdoor Unit Model A5CK 40ER Model A5LC 40CR 1 Phase...