Troubleshooting
ACK-E-2009
Troubleshooting
Error Code / Fault Condition
When a malfunction of the air conditioner unit is detected, immediately switch off the main power supply before
proceeding with the following troubleshooting procedures.
The following are common fault conditions and simple troubleshooting tips. If any other fault conditions which
are not listed occur, contact your nearest local dealer. DO NOT attempt to troubleshoot the unit by yourself.
No
Fault conditions
Possible causes / corrective actions
1
The air conditioner unit will not resume after
power failure.
The auto restart function is not functioning.
Please turn on the unit with the wireless /
wired controller.
•
2
The compressor does not operate 3 minutes
after the air conditioner unit is started.
Protection against frequent starting.
Wait for 3 or 4 minutes for the compressor to
start operating by it self.
•
•
3
The air
fl
ow is too slow or room cannot be
cooled suf
fi
ciently.
The air
fi
lter is dirty.
The doors and windows are opened.
The air suction and discharge of both indoor
and outdoor units are clogged or blocked.
The regulated temperature or temperature
setting is not low enough.
•
•
•
•
4
Discharge air
fl
ow has bad odor.
Cigarettes, smoke particles, perfume and
others, which might have adhered onto the
coil, may cause odor.
Contact your nearest dealer.
•
•
5
Condensation on the front air grille of the indoor
unit.
This is caused by air humidity after an
extended period of operation.
The set temperature is too low. Increase the
temperature setting and operate the unit at
high fan speed.
•
•
6
Water
fl
owing out from the air conditioner.
Switch off the unit and contact your nearest
dealer. This might be due to tilted installation.
•
7
Hissing air
fl
ow sound from the air conditioner
unit during operation.
Liquid refrigerant
fl
owing into the evaporator
coil.
•
8
The wireless controller display is dim.
The batteries are discharged.
The batteries are not correctly inserted.
The assembly is not good.
•
•
•
9
Compressor operates continuously.
Dirty air
fi
lter. Clean the air
fi
lter.
Temperature setting too low (cooling). Use
higher temperature setting.
Temperature setting too high (heating), Use
lower temperature setting.
•
•
•
10
No cool air comes out during cooling cycle, or
no hot air comes out during heating cycle.
Temperature setting too high (cooling). Use
lower temperature setting.
Temperature setting too low (heating). Use
higher temperature setting.
•
•
11
On heating cycle, warm air does not come out.
Unit is in defrost mode. Heating operation will
resume after defrost cycle ends.
•
13_Troubleshooting_A.indd 123
13_Troubleshooting_A.indd 123
4/6/2009 11:17:08 AM
4/6/2009 11:17:08 AM
Содержание A5CK 20E
Страница 115: ...113 Wiring Diagram ACK E 2009 08024 105059 Indoor Unit Outdoor Unit Model ACK A5CK 40E Model ALC A5LC 35 40C 1 Phase...
Страница 116: ...114 ACK E 2009 Wiring Diagram 08024 105061 Indoor Unit Outdoor Unit Model ACK A5CK 40 50E Model ALC A5LC 40 50C 3 Phase...
Страница 118: ...116 ACK E 2009 Wiring Diagram 08024 105063 Indoor Unit Outdoor Unit Model ACK 40ER Model ALC 35 40CR 1 Phase...
Страница 119: ...117 Wiring Diagram ACK E 2009 08024 105064 Indoor Unit Outdoor Unit Model ACK 40 50ER Model ALC 35 40CR 3 Phase ALC 50CR...
Страница 120: ...118 ACK E 2009 Wiring Diagram 08024 105065 Indoor Unit Outdoor Unit Model A5CK 40ER Model A5LC 35CR 1 Phase...
Страница 121: ...119 Wiring Diagram ACK E 2009 08024 105066 Indoor Unit Outdoor Unit Model A5CK 40ER Model A5LC 40CR 1 Phase...