Ascon Tecnologic - B05B - OPERATING INSTRUCTIONS - PAG. 10

HE

 

To control an heating device in neutral zone control 
mode (

HC

 = 

nr

);

L1

 

Output of the shop window light managed by 

Normal

/

Eco

 mode. This output will be ON in 

Normal

 mode 

and OFF in 

Eco

 mode operation;

L2

 

Output of the light internal to the cell managed by a 
digital input.  This output will be ON when door is open  
(only if 

o

1

2

3

);

-d

 

Defrost output with NC contact;

oF

 

Output disabled.

If one of the output is configured as 

auxiliary

 (

o

o

 = 

Au

), 

the function carried out by auxiliary output is defined by the 
parameter 

Fo

 and the function is conditioned by the time set 

in parameter 

tu

.

The parameter 

Fo

 can be configured for the following functions:

oF

 

Auxiliary output not active;

1. 

Delayed temperature control output.  The auxiliary output 
is activated with a delay from the activation of the 

ot

 

output, the delay can be set with parameter 

tu

.  The 

Aux

 output is then turned OFF at the same time as the 

ot

 output is disabled.  This function mode can be used 

as a command for a second compressor or for all other 
working utilities according to the same 

ot

 output condi-

tions, but which must be delayed after the start up of the 
compressor to avoid excessive current absorption;

2. 

Activation by digital input: the output is activated by a digital 
input suitably configured (

o

F

 = 

9

).  The commands have a 

toggle function which means that at the first impulse, the 
output is activated while at the second is disabled.  In this 
mode, the 

AUX

 output can be turned OFF automatically 

after a certain time that can be set at parameter 

tu

. With 

tu

 = 

oF

 the output is activated and deactivated only manu-

ally through a digital input.  Differently, the output, once 
activated, is turned OFF automatically after the 

tu

 time has 

elapsed.  This mode can be used to control the cell light, 
the anti fogging resistances or other utilities.

The internal buzzer (when present) can be configured by 
parameter 

bu

 for the following functions:

oF

 

Buzzer always disabled;

1. 

The Buzzer signals the active alarms only;

2. 

The Buzzer signals the key pressed only (no alarm);

3. 

The Buzzer signals the active alarms (continuous sound) 
and the key pressed;

4. 

The Buzzer signals the active alarms (with intermittent 
beep) and the key pressed.

5.6 

Temperature control

All parameters relative to the temperature control are con-
tained in the 

-re

 group.

The instrument 

control

 is 

ON/OFF

 and acts on the 

ot

 and 

HE

 

outputs

 depending on the 

PR1

 probe measuring, the 

active 

Set Point(s)

 

S1

 (or 

S2

S3

SE

SH

), the Histeresys 

d

 (or 

Ed 

and/or 

Hd

) and the function mode 

HC

.

Through 

HC

 parameter is possible to set the following operations:

C

 Cooling;

H

 Heating;

nr

 

Neutral zone;

HC

 

Cooling and Heating with 2 independent Set Points;

C3

 

Cooling with 3 automatic modes of intervention.

5.6.1 

Cooling and Heating (

C

 or 

H

)

SP

Temp.

d

time

off

off

SP

Temp.

d

time

ON

HC

 = 

C

HC

 = 

H

off

off

ON

ON

ON

ON

ON

ot

 output

ot

 output

Pr1

Pr1

Depending on the function mode programmed with parameter 

HC

 the differential is automatically considered by the control-

ler with positive values for a 

Refrigeration

 control (

HC

 = 

C

) or 

negative values for a 

Heating

 control (

rHC

 = 

H

).

Note: 

The 

P03

 display panel has only one LED   to show the 

Heat or Cool action, while the 

P34

 has 2 LEDs, one   

for the 

Heating

 action and one   for the 

Cooling

 action.

5.6.2 

Neutral zone (

nr

)

S1

HE

 output

ot

 output

off

ON

Temp.

time

d
d

off

off

ON

ON

PR1 

HC

 = 

nr

When 

HC

 = 

nr

, the output configured as 

ot

 operates with 

cooling

 action (such as 

HC

 = 

C

) while the output configured 

as 

HE

 operates with 

heating

 action (as 

HC

 = 

H

).  In this 

case, the set point for both outputs is the active one between 

S1

S2

S3

SE

SH

 and the intervention differential (

d

Ed

 or 

Hd

) is automatically considered by the controller as positive 

for the cooling action and negative for the heating one.

5.6.3 

Heating and cooling with 2 independent 
Set Points (

HC

)

S1

SH

off

off

off

Temp.

time

d

Hd

off

off

off

ON

ON

ON

ON

ON

HE

 output

ot

 output

PR1

As in the previous case, when 

HC

 = 

HC

, the output config-

ured as 

ot

 operates with 

cooling

 action (such as 

HC

 = 

C

while the output configured as 

HE

 operates with 

heating

 ac-

tion (as 

HC

 = 

H

), but now, the Set Point of the 

ot

 output is the 

one 

set as active

, while the one of the 

HE

 output is the 

SH

 

Set Point.  The intervention differential for the 

ot

 output is the 

active one (

d

Ed

 or 

Hd

) and is considered by the controller 

as 

positive

 (because is a 

cooling

 action) while the interven-

tion differential for the 

HE

 output is the 

Hd

 one and is consid-

ered 

negative

 (because is a 

heating

 action).

In this functioning mode, the activation of the 

turbo

 cycle 

causes the instrument to operate with neutral zone setting 
with 

SH

 Set Point.

Содержание B05B

Страница 1: ...ng the temperature or continuous time compressor operating through stopping the compressor electric heating or hot gas cycle inversion The appliance has special defrosting optimisation func tions and...

Страница 2: ...n be used to start stop a manual defrost In parameter programming or variables display mode is used for selecting the parameters and for increas ing the values to be set In programming mode if pressed...

Страница 3: ...is possible to select which Set Point is to be set as active S1 S2 S3 Once selected the active Set Point press the key or wait 10 s after which the instrument makes the selected Set Point active and...

Страница 4: ...pro tected if instead the SET LED is steady ON the parameter is programmable without password is unprotected To change the parameter visibility press the key and while keeping it pressed press also t...

Страница 5: ...ut adequate protections The instrument used with NTC 103AT11 probe identifiable by the printed code 103AT 11 visible on the sensor part is compliant with standard EN 13485 Thermometers for measuring t...

Страница 6: ...igher than the maximum electricity current permitted As the instrument is built in equipment with permanent con nection inside housing it is not equipped with either switches or internal devices to pr...

Страница 7: ...d With the key pressed for 1 s if UF 2 Using a Digital Input if parameter oF 7 where o is the number of the digital input o 1 4 for P03 or o 2 4 for P34 5 2 Normal Economic and Turbo operation The con...

Страница 8: ...oods temperature recovery after which it returns to normal operation mode and so on Temp SE SP SH Hd Ed tt 2 tC tC time Normal Turbo Turbo Et 1 d Pr1 1 The Et time count is reset at each door opening...

Страница 9: ...nstrument alternately displays the label AL and the variable set at parameter dS 6 Normal ECO mode selection with NO contact at digital input closure the instrument switches to the ECO mode operation...

Страница 10: ...d the key pressed 5 6 Temperature control All parameters relative to the temperature control are con tained in the re group The instrument control is ON OFF and acts on the ot and HE outputs depending...

Страница 11: ...urned ON last time delay between two switching ON off off off ON S1 Temp time d P3 P3 P3 ot output ON ON Pr1 During the output inhibition the LED of the control output blinks It is also possible to pr...

Страница 12: ...rrectly set it is possible to avoid many non necessary defrosting cycles and therefore save energy that could instead happens in normal operation when to guar antee the system efficiency the interval...

Страница 13: ...mperature has not reached the lock value or the SP d value or is elapsed the time set at parameter dA dL Lb Shows the label dF during the defrost cycle and Pd after the defrost until at the end of def...

Страница 14: ...rms and their differentials 1d 2d With parameters 1y and 2y it is also possible to define whether the alarm thresholds 1H 2H 1L 2L are absolute or relative to the Set Point Depending on the desired op...

Страница 15: ...to disable the control outputs when the main voltage is lower or higher than the values set at parameters LU Low voltage Alarm expressed in Volt x 10 HU High voltage Alarm expressed in Volt x 10 At th...

Страница 16: ...remote display To the instrument it is possible to connect the remote display TVR Y through the special cable that can have a maximum length of 10 m The TVR Y device is directly supplied by the instru...

Страница 17: ...C F 0 0 11 CU 280C Measure offset display only 30 0 30 0 C F 30 9 9 9 9 30 C F 0 0 12 P2 280D Probe Pr2 input function 0 oF 1 EP 2 Au 3 cd 4 r1 5 dG oF No function EP Evaporator Au Aux cd Condenser r1...

Страница 18: ...oF 30 tE 2820 Defrost stop temperature 99 9 999 0 C F 99 9 9 9 9 10 99 C F 8 0 31 Ei 2821 Defrost interval for evaporator probe error 0 oF 0 01 99 59 h min oF No interval 01 59 min 01 99 h 6 32 EE 28...

Страница 19: ...Description Range MODBUS R W Range display Default display Note 56 1y 283C Temperature alarms 1 Type 1 10 1 Pr1 absolute with label H L 2 Pr1 Relative with label H L 3 Au absolute with label H L 4 Au...

Страница 20: ...Au Auxiliary At Silenceable alarm AL Not silenceable Alarm An Stored alarm t Silenceable alarm with inverse logic Output open in alarm L Not silenceable Alarm with inverse logic Output open in alarm n...

Страница 21: ...SH and SE limits 2 Direct selection of Active Set Point between the 3 pre set Set Points S1 S2 and S3 using the keys 2 83 PP 285B Access Password to parameter functions 0 oF 1 99 oF No password 1 999...

Страница 22: ...e shipped to Ascon Tecnologic with a detailed description of the faults found without any fees or charge for Ascon Tecnologic except in the event of alterna tive agreements 10 TECHNICAL DATA 10 1 Elec...

Страница 23: ...ir S A 1 50 C 90 C with probe NTC 103AT11 11 INSTRUMENT ORDERING CODE 11 1 B05B Instrument Code MODEL B05B Controller a POWER SUPPLY H 100 230 VAC b OUTPUT 1 OUT 1 H Relay SPST NO 30A AC1 for resistiv...

Страница 24: ...Ascon Tecnologic B05B OPERATING INSTRUCTIONS PAG 24...

Отзывы: