TD 92319GB
2008-11-10/ Ver. D
User Manual
Ascom i75 VoWiFi Handset
37
14.5 Man-down Alarm
Note:
The No-movement alarm requires that the licence option is made available in the
handset. For information on how to add a licence, refer to
Configuration Manual, Ascom
i75 VoWiFi Handset
TD 92431GB
.
You can activate/deactivate the alarm function in the menu, see
15.5.7
Deactivate/
Activate Man-down alarm
1
on page 46, or by programming a Soft/Hot key as a short-cut
to the function, see
15.5.8
Edit a Soft key
on page 47. The Soft/Hot key changes the state
of the alarm, i.e. if it is deactivated it will be activated and vice verse. Press the Soft key, or
press and hold the Hot key, to put the alarm in or out of operation, respectively.
The
Man-down alarm on
icon on your display is an indication that the Man-down alarm is
in operation.
Send Man-down alarm
The Man-down alarm will go off when the handset is tilted more than 45º for a preset
period of time (default 30 seconds), for example if you fall. Before the alarm is activated a
warning signal sounds and the
Man-down alarm on
icon starts to flash. If you do not
cancel the alarm by pressing a key, it is sent and
Man-down alarm
1
is shown in the display.
Activate Man-down alarm after sending
When the man-down alarm has been sent, it is made active again by moving the handset
to upright position or pressing a key.
14.5.1 Delay Time for No-movement and Man-down Alarms Warning Signal
By setting a parameter, the time before the warning for no-movement and man-down
alarms can be delayed for ten minutes, i.e. no-movement and man-down will not be
detected during the time period. When the warning signal sounds, press the Mute button
to delay the time to next warning for up to ten minutes.
14.6 Alarm with Data
Additional data for example a location code, can be sent along with an alarm. The data
must manually be defined and stored by the user via the menu. This is a system dependent
function.
14.7 Automatic Call after an Alarm
The handset can be programmed to call a predefined telephone number directly after an
alarm. Each alarm type in the handset must be programmed with the specific telephone
number. It can be any external or internal telephone number but also a pre-defined group
of handsets.
This is a system dependent function that also require a parameter setting in the IP handset.
Note:
An ongoing call will be disconnected, unless it is an alarm call, and an incoming call
will be rejected when the alarm is transmitted. Then the telephone number associated
with the alarm will be dialled.
1.The information text can be changed using a parameter in the handset