TD 92232GB
2005-06-15 / Ver.G
Installation Guide
ELISE2
22
4.13 Connection of Ethernet
If ELISE2 is connected directly to a PC, a crossover cable has to be used. If ELISE2 is
connected to a HUB, an ordinary (straight through pinouts) cable has to be used. The
cable supplied is an ordinary cable.
Connect the Ethernet cable to connector J20, see
below.
It is recommended to break off a suitable section before inserting the Ethernet cable, see
Figure 19. Connection of Ethernet cable
4.14 Installation Test Procedure
1
If the ELISE2 module is connected to a Central Unit, the indicator will light steadily
green within 90 seconds.
If the indicator continues to flash orange, check:
• Connections on ELISE2
• ELISE2 has a correct System 900 address
Note:
Check also the application documentation for trouble-shooting information.
If the indicator starts to blink red, check:
• IP address
• Network connections
• Licence
• Module key
If everything seems to be OK but the function indicator still flashes, the fault is
probably located outside the ELISE2:
Check the other System 900 units according to document
System Installation, On-
site Paging System, TD 90227GB,
or contact your dealer.
2
Open the administrator page in a browser and navigate to "Troubleshoot". Use the
information log and tools given to test that ELISE2 is functioning properly.
3
Replace the cover.
4
When all other units are installed, perform the system test described in
System
Installation, On-site Paging System, TD 90227GB
.
027
Ethernet