Installation Guide
ELISE2
14
4.7
System 900 Addressing
The System 900 address consists of two hexadecimal digits that are selected by the eight
sections of the address switch, SW2. Sections 5-8 of the switch select the first (most
significant) digit and section 1-4 select the second (least significant) digit. The address
must not be the same as any other System 900 unit address (see document
System
Installation, On-site Paging System, TD 90227GB
for more information
).
Figure 8. The ELISE2 module addressing switch.
4.8
Connection of System Bus
The ELISE2 module can be installed together with other System 900 units, either via
modular system bus cabling or via twisted-pair lines.