Installation Guide
ELISE2

8

Authentication

There are two different users in all ELISE2 products; admin and sysadmin. 

The user 

admin 

has the default password "changeme" and is used for administration and 

simple troubleshooting of the product. The admin has permission to change all passwords 
except the sysadmin password.

The user 

sysadmin

 has the default password "setmeup" and is used for advanced 

troubleshooting. The user also has access to all administration pages. The sysadmin has 
permission to change passwords for all users in the product.

In addition, there are two other users in some ELISE2 products. One is called 

user

 and the 

default password is "password". This user is product dependent and what it is used for is 
described in corresponding product documentation. This user does not have access to the 
administration pages where passwords normally are changed. The user can change its 
own password on the following page; 
http://xxx.xxx.xxx.xxx/admin/public/user_chpass.shtml. The password can also be changed 
by the users admin and sysadmin.

The other user is called 

ftpuser

 and the default password is "changemetoo". The user is 

available in products with a FTP area. The user can change its own password on the 
following page; http://xxx.xxx.xxx.xxx/admin/public/ftpuser_chpass.shtml.

Administration

To access the web pages below, the user 

admin

 is used. 

The web page "xxx.xxx.xxx.xxx/admin" is used in most occasions, for example:

• System setup, i.e. System 900 configuration

• Troubleshooting information

• Changing passwords

On the following occasions, the web page "xxx.xxx.xxx.xxx/system" must be used.

• Current software installation has to be replaced.

• No software is installed on ELISE2.

• Compact Flash image update or installation

The system page can also be used when configuring network parameters.

4

Installation

ELISE2 should be placed in a dry environment with a temperature range of 0 to +40°C.

The ELISE2 module can be connected via system bus cabling, or via twisted-pairs together 
with other units in the System 900. The ELISE2 modules can communicate with each other 
via the TCP/IP network.

IMPORTANT:

The ELISE2 module must be mounted in a vertical position to ensure 
sufficient cooling for the electrical components.

IMPORTANT:

Always follow the instructions in 

3.2 Power Down and Restart of ELISE2 

on 

page 4

 

when disconnecting the power to the ELISE2 module.

Содержание ELISE2

Страница 1: ...TD 92232GB 2005 06 15 Ver G Installation Guide ELISE2...

Страница 2: ...Units 13 4 7 System 900 Addressing 14 4 8 Connection of System Bus 14 4 9 Connection of Supply Voltage 16 4 10 Additional Connections 17 4 11 Activation of Battery 19 4 12 Setup of Network Parameters...

Страница 3: ...nt and therefore described in the application documentation The parameter setup of ELISE2 is done with a web browser Figure 1 The ELISE2 module Supply voltage 12 24 V DC 10 Current consumption max 0 4...

Страница 4: ...ard Description Figure 2 The ELISE2 circuit board 002 J2 IC2 J10 J16 J15 J4 J13 J12 J11 J8 J7 J24 J14 J6 J5 J20 S3 LED6 RS232 3 ETH 900 900 RS232 2 RS232 1 LED7 S4 S5 S1 S2 IC24 J22 J9 IC1 CPU BAT1 SW...

Страница 5: ...e is not used J1 Jumper that activates the backup battery Jumper pin 2 3 to activate J4 For grounding and production test J15 Jumper that determines if the Error relay output should be active when the...

Страница 6: ...ISE2 restarts wait until the Function Indicator is not indicating starting up flashing orange before pressing SW4 again Restart There are two ways to restart an ELISE2 following the instruction above...

Страница 7: ...ence How the mode functions is application dependent For more exact information about the functionality during unlicensed mode see the application documentation In unlicensed mode it is possible to en...

Страница 8: ...Set all sections on SW3 to OFF 2 Open the page System Setup General on the administration web page and check that the correct licence is entered 3 Press Reboot 3 5 Function Indicator Figure 4 Status...

Страница 9: ...ation and Authentication Administration on ELISE2 is done from a web browser In order to access the administration pages a user name and password have to be given IMPORTANT The default passwords have...

Страница 10: ...alled ftpuser and the default password is changemetoo The user is available in products with a FTP area The user can change its own password on the following page http xxx xxx xxx xxx admin public ftp...

Страница 11: ...ructions in 4 7 System 900 Addressing on page 14 6 Connect the system bus follow instructions in 4 8 Connection of System Bus on page 14 and 4 9 Connection of Supply Voltage on page 16 7 Optionally co...

Страница 12: ...itable section 2 Run the wiring out through the partition Wiring can be run three ways from the ELISE2 module Remove the rectangular covers and run the cabling out through the side 1 Break off section...

Страница 13: ...to communicate with for example an Alarm Module or Output Module The same information that can be received when the ELISE2 is connected to an A bus with Central Unit can also be received when it is co...

Страница 14: ...Distribution on page 24 and documentation for the System 900 Required Hardware Modifications When ELISE2 shall control the communication on the A B bus jumper points S4 and S5 has to be soldered see...

Страница 15: ...ree space of about 150 mm above and 50 mm below the unit 4 6 Mounting Together with Other Units 1 Remove the rectangular 1 and circular 2 covers 2 The rectangular covers are used to fasten units to ea...

Страница 16: ...e same as any other System 900 unit address see document System Installation On site Paging System TD 90227GB for more information Figure 8 The ELISE2 module addressing switch 4 8 Connection of System...

Страница 17: ...other unit Note Make sure connectors are correctly inserted Bus Connection to Screw Terminals If system bus cable is not used connections are made with twisted pairs to screw connector J24 Figure 9 Co...

Страница 18: ...stallation On site Paging System TD 90227GB under Power Supply Figure 10 Connection of supply voltage Figure 11 Ferrite bead attached and wired in the module 1 To be able to fit the ferrite bead break...

Страница 19: ...ring is set to 1 2 the circuit is open and the error relay output is inactive At power up or restart of the ELISE2 the relay is released until the applications are working properly If the relay is rel...

Страница 20: ...uts are software dependent Two digital inputs and two digital outputs can be connected via J16 The outputs are of open collector type and the output signals are dimensioned for 100 mA at max 12 V A pu...

Страница 21: ...battery by closing jumper J1 on the circuit board Jumper pin 2 3 to activate Figure 17 Battery placement The backup battery is a 3V lithium battery At any interruption in the ordinary power supply the...

Страница 22: ...e network setup IP address 192 5 36 229 If the function indicator is red check that supply voltage is 12 5 Vdc 10 4 To be able to access ELISE2 from a PC the PC has to belong to the same network as EL...

Страница 23: ...OFF Reboot ELISE2 by navigating to Reboot 10 Return to the program Route to ELISE and press Detach to remove the ELISE2 network setup IP address from the route table Close the program 11 When ELISE2...

Страница 24: ...s If the indicator continues to flash orange check Connections on ELISE2 ELISE2 has a correct System 900 address Note Check also the application documentation for trouble shooting information If the i...

Страница 25: ...tion specific pages The administration pages that are common to all ELISE2 will display date and time in the following format YYYY MM DD HH MM SS for example 2000 01 31 13 30 00 This format for date a...

Страница 26: ...onfigured to distribute the data to a module It is also possible to address the System 900 interface on another module by entering its IP address instead of 127 0 0 1 localhost Module addressing 127 0...

Страница 27: ...into the cabinet 6 If the Compact Flash is not preprogrammed with a valid IP address follow the instructions in 4 12 Setup of Network Parameters on page 20 else connect the power cable 7 Replace the c...

Страница 28: ...hat handles the remote connection 5 4 Installing an Image on an empty Compact Flash An image can also be installed on an empty Compact Flash 1 Set section one and four in SW3 to ON to set the ELISE2 i...

Страница 29: ...the screw connectors from the circuit board 1 4 Press the four holding clips to release the circuit board 2 5 Remove the circuit board 3 6 Install the new circuit board in the case and make sure the c...

Страница 30: ...flash micro controller J3 Male connector to be put on J9 on ELISE2 circuit board Pin 12 cut off J4 Male connector to be put on J10 on ELISE2 circuit board SW1 For service IC1 Flash memory IC3 Neuron...

Страница 31: ...pins of the LPB with the female connector of the ELISE2 then press the LPB down firmly To avoid misalignment the pin 12 on the J3 connector of the LPB is cut off and the corresponding hole on the J9...

Страница 32: ...cm Only use pins 1 and 2 for connection of the LON bus in out Pins 3 and 4 can be used for connection of other LON devices for example SLA See figure 22 below Figure 22 Cabling of screw connector J1 6...

Отзывы: