Maps and Registers
ATCA-7540 Installation and Use (6806871A01A)
163
5.1.26 Telecom Clock Supervision Registers
All incoming telecom clocks can be monitored and measured in the range from 1 Hz to
166 MHz. Up to four different clock inputs may be monitored. See the following table.
When at least one bit shown in
is set, the corresponding status bit
CLK_MONITOR_FINISHED shown in
is also set.
Table 5-90. Supervised Telecom Clocks Reference List
Number
Name
Description
0
SYSCLK_IN_CLK1A
CLK1A from backplane
1
SYSCLK_IN_CLK1B
CLK1B from backplane
2
SYSCLK_IN_CLK2A
CLK2A from backplane
3
SYSCLK_IN_CLK2B
CLK2B from backplane
Table 5-91. Telecom Clock Monitor Control Register
Address: 0x60
Bit
Description
Default
Access
3:0
Enable supervised Telecom Clock 0 to 3
Set corresponding bit enable monitoring.
0
LPC: r/w
7:4
Reserved
0
r
Table 5-92. Telecom Clock Monitor Status Register
Address: 0x61
Bit
Description
Default
Access
3:0
Result available for supervised Telecom Clock 0 to 3.
Corresponding bit is set when measurement has
finished.
Clearing bit triggers new measurement.
0
LPC: r/w1c
7:4
Reserved
0
r
Содержание ATCA-7540
Страница 1: ...ATCA 7540 Installation and Use P N 6806871A01A December 2018 ...
Страница 12: ...12 ATCA 7540 Installation and Use 6806871A01A Contents ...
Страница 28: ...About this Manual 28 ATCA 7540 Installation and Use 6806871A01A ...
Страница 34: ...Safety Notes 34 ATCA 7540 Installation and Use 6806871A01A ...
Страница 66: ...Hardware Preparation and Installation 66 ATCA 7540 Installation and Use 6806871A01A ...
Страница 276: ...Supported IPMI Commands 276 ATCA 7540 Installation and Use 6806871A01A ...
Страница 322: ...Related Documentation 322 ATCA 7540 Installation and Use 6806871A01A ...
Страница 323: ......