DLC170 Function Modules Installation and Operations Manual
DLC170 Function Modules
shows the DLC170AD configuration switch SW2 located on top of the PCB.
Figure 4.
DLC170AD Configuration Switch SW2
describes the DIP switch SW2 configuration options. The factory-set configuration settings are shown
in bold type.
Table 3.
DIP Switch SW2 Settings
Function
Selected Operation
Position
S1
S2
S3
S4
S5
S6
S7
S8
Audio Embed
Enabled
ON
Disabled
OFF
Reserved
Must be ON
ON
Audio
Destination
Group 1
ON
ON
Group 2
OFF
ON
Group 3
ON
OFF
Group 4
OFF
OFF
Audio Mode
24 bits
ON
20 bits
OFF
Reserved
Must be ON
ON
SFP Alarms
Enabled
ON
Disabled
OFF
EMS Override
Enabled: DL Manager can change
the DLC170AD module
configuration.
ON
Disabled: DL Manager cannot
change the DLC170AD module
configuration.
1
OFF
1. If the module is operating in EMS Override mode, as indicated by a green OK LED on the front panel, thenthe EMS
Override DIP switch has no effect until you use DL Manager to take the module out of override mode and set it to local
mode (see the
DL Manager Setup and Operations Manual
).