63
Note: The integrated cooling system keeps the
CMOS imager at a constant 32 °C. When the
camera is operated in high temperatures,
it may be necessary to support the internal
cooling by means of an external fan, which
is available as an optional accessory.
Standard Reset
A standard reset restores the factory settings for
user-accessible and internal controls of the image
processing module. To perform a standard reset:
Enter "Diagnostics", "Standard Reset".
•
Confirm the standard reset by entering
•
"Yes", or cancel by entering "No".
When the power LED on the camera backside
•
starts blinking red, restart the camera using the
main power switch to complete the standard reset.
The camera will return to the user mode it was
set to when the standard reset was performed.
After a standard reset, the camera will default to these settings:
White Balance: 3200 K
HD-SDI Mode: HD422 25PsF
Output Range: Normal Range (YCbCr)
Color Matrix:
3200 K (not displayed in Standard User Mode menu)
Contrast Char.: EI 200
SD Video Mode: PAL
Status
Standard Reset
Cancel