![Aros SIRIO EASY 1500 Скачать руководство пользователя страница 46](http://html1.mh-extra.com/html/aros/sirio-easy-1500/sirio-easy-1500_installation-and-user-manual_2975480046.webp)
- 46 -
‘SYSTEM
INFO’
M
ENU
Screen 1:
shows the inverter type ID code on the first line and its serial number on the second.
Screen 2:
shows firmware revision on the first line and the nation set during installation on the second.
Screen 3:
shows the address used on the RS485/422 bus (optional) on the first line and an internal ID code for communicating with
customer service on the second line.
The following screens show the status of the settings that can be requested by grid operators and activated using the dedicated
configuration software only.
Screen 4:
Summarises the configuration of the interface protection, displaying the protections enabled.
„V: L2 L1 H1 H2 EM‟, the first line shows the voltage protections enabled
„F: L2 L1 H1 H2 CO‟: the second line shows the frequency protections enabled
For example on line V: H2 indicates the maximum external voltage protection, H1 indicates the maximum internal
voltage protection (average over 10 minutes in some countries
), therefore, „H‟ indicates the maximum protections, „L‟ the
minimum protections, „1‟ the most restrictive thresholds and „2‟ the most permissive thresholds.
With reference to the chapter on the communication interface, „EM‟ indicates that the emergency signal is enabled and
'CO' that has the communication present signal is enabled.
Screen 5:
The first line shows the enabled functions to limit the active power fed.
„REP‟: limitation controlled by the grid operator.
„FPD‟: limit set depending on the grid frequency.
„VPD‟: limit for high grid voltage.
The second line shows the functions enabled to generate reactive power.
„REQ‟: reactive power controlled by the grid operator.
„CFP‟: power factor depending on the active power fed.
„QFVa‟ / 'QFVb': reactive power control depending on the grid voltage according to the “a” or “b” curve in the CEI 0-21
regulation.
Screen 6:
„LVFRT ON‟ / „LVFRT OFF‟: indicates whether the Low Voltage Fault Ride Through function (insensitivity to falls in grid
voltage) is enabled.
‘DISPLAY’
M
ENU
„CONTRAST‟
Display contrast can be adjusted: press ↑ to increase, press ↓ to decrease. Press
to confirm.
On any menu, the „CONTRAST‟ menu can always be accessed by pressing the ↓ and buttons together.
'BACKLIGHT'„
Display backlight can be adjusted: press ↑ to increase, press ↓ to decrease. Press
to confirm.