Atlanta
English
05060191 00 06-2021
19
24. Spare parts
Use only original spare parts
•
replace the parts before wearing excessively to avoid damage to persons or property
•
carry out scheduled maintenance as provided in the agreement
25.
Troubleshooting
Problem
Possible causes
Possible solutions
The cabinet
stops or does
not start
•
power black-out
•
check the cause of the black-out
•
master switch turned off
•
turn on the switch
•
plug detached
•
insert the plug
•
breakers triggered (fuses,
thermal breakers/differential
switches)
•
check the temperature of the condensing
unit
•
electric controller faulty
•
replace the controller
once the electrical power supply has been restored, check that all the
electrical equipment in the store will restart without triggering the over-
load protection devices; otherwise, modify the system to differentiate the
start-up of the various devices.
i
If power is not restored in a short time, store the goods in a cold room to
maintain the storage temperature.
The cabinet
does not
cool
sufficiently
•
the cabinet is in the defrosting
phase
•
wait for defrost to finish (~ 30min)
•
air inlets are obstructed
•
release air inlets
•
the load is not distributed even-
ly
•
load the goods in an orderly fashion (Fig.13)
•
the cabinet is next to air cur-
rents or heat sources
•
check the position of the cabinet inside the
store chap.12
•
the cabinet is not levelled
•
level the cabinet see chap.13
•
evaporator frozen
•
thaw it
The engine is
noisy
•
screws and bolts are not tight-
ened
•
tighten the bolts and screws
•
the cabinet is not levelled
•
level the cabinet chap.13
Condensate
•
poor room conditions
•
check the position of the cabinet inside the
store chap.13
•
poor air ventilation
•
check the operation of fans and wiring
•
the window heaters do not work
•
check electrical connections
•
check the operation of heating elements
•
the windows are not closed
properly
•
close the windows properly
Содержание Atlanta