Safety Information
Patient Entrance / Exit –
Caregiver should always aid patient in exiting the bed.
Make sure a capable patient knows how to get out of bed safely (and, if necessary,
KRZWRUHOHDVHWKHVLGHUDLOVLQFDVHRI¿UHRURWKHUHPHUJHQF\
Brakes –
Caster brakes should always be locked once the bed is in position. Verify wheels
are locked before any patient transfer to or from the bed.
Bed Height –
7RPLQLPL]HULVNRIIDOOVRULQMXU\WKHEHGVKRXOGDOZD\VEHLQWKHORZHVW
practical position when the patient is unattended.
Bed Frame –
Always use a standard healthcare bed frame with this mattress, with any
safeguards or protocols that may be appropriate. Bed frame and side rails (if used) must
EHSURSHUO\VL]HGUHODWLYHWRWKHPDWWUHVVWRKHOSPLQLPL]HDQ\JDSVWKDWPLJKWHQWUDS
a patient's head or body. It is recommended that bed and side rails (if used) comply with
all applicable regulations and protocols.
CPR –
Level the bed and disconnect pump (if present). Lower side rails and initiate
CPR per facility protocols. Consider use of backboard if indicated. After CPR, remove
EDFNERDUGLIXVHGUHFRQQHFWSXPSLISUHVHQWUDLVHVLGHUDLOVDQGUHFRQ¿JXUHEHGDQG
accessories as in initial placement.
Head of Bed Elevation –
Keep head of bed as low as possible to help prevent patient
migration.
Side Rails / Patient Restraints
- Whether and how to use side rails or restraints is
DGHFLVLRQWKDWVKRXOGEHEDVHGRQHDFKSDWLHQW¶VQHHGVDQGVKRXOGEHPDGHE\WKH
SDWLHQWDQGWKHSDWLHQW¶VIDPLO\SK\VLFLDQDQGFDUHJLYHUVZLWKIDFLOLW\SURWRFROVLQ
PLQG&DUHJLYHUVVKRXOGDVVHVVULVNVDQGEHQH¿WVRIVLGHUDLOUHVWUDLQWXVHLQFOXGLQJ
entrapment and patient falls from bed) in conjunction with individual patient needs, and
should discuss use or non-use with patient and / or family. Consider not only the clinical
and other needs of the patient but also the risks of fatal or serious injury from falling
out of bed and from patient entrapment in or around the side rails, restraints or other
accessories. Consult the local Competent Authority or Government Agency for Medical
'HYLFH6DIHW\IRUVSHFL¿FORFDOJXLGDQFH&RQVXOWDFDUHJLYHUDQGFDUHIXOO\FRQVLGHUWKH
XVHRIEROVWHUVSRVLWLRQLQJDLGVRUÀRRUSDGVHVSHFLDOO\ZLWKFRQIXVHGUHVWOHVVRUDJLWDWHG
patients. It is recommended that side rails (if used) be locked in the full upright position
when the patient is unattended. Make sure a capable patient knows how to get out of bed
VDIHO\DQGLIQHFHVVDU\KRZWRUHOHDVHWKHVLGHUDLOVLQFDVHRI¿UHRURWKHUHPHUJHQF\
Monitor patient frequently to guard against patient entrapment.
CAUTION: When selecting a standard mattress, ensure the distance
between top of side rails (if used) and top of mattress (without
compression) is at least 8.66 in (220 mm) to help prevent inadvertent
bed exit or falls. Consider individual patient size, position (relative
to the top of the side rail) and patient condition in assessing fall risk.
Skin Care –
Monitor skin conditions regularly and consider adjunct or alternative therapies
for high acuity patients. Give extra attention to any possible pressure points and locations
where moisture or incontinence may occur or collect. Early intervention may be essential
to preventing skin breakdown.
I.V. and Drainage Tubes
- I.V. and drainage tubes should always have slack for
alternating pressure or rotation and other patient movements.
Содержание AtmosAir 9000A
Страница 4: ...iv Intentionally left blank ...
Страница 28: ...xxiv Absichtlich freigelassen ...
Страница 52: ...xlviii Opzettelijk blanco gelaten ...
Страница 76: ...lxxii Laissé vierge intentionnellement ...
Страница 100: ...xcvi Lasciato intenzionalmente in bianco ...
Страница 124: ...cxx Intencionalmente vacío ...
Страница 148: ...cxliv Tom side ...
Страница 172: ...clxviii Denna sida har avsiktligen lämnats tom ...
Страница 196: ...cxcii Página intencionalmente deixada em branco ...
Страница 220: ...FF Yඈ g HOOLNOH ERú EÕUDNÕOPÕúWÕU ...
Страница 244: ...ccxl ǹijȒȞİIJĮȚ țİȞȩ İț ʌȡȠșȑıİȦȢ ...
Страница 258: ... AtmosAir 9000A AtmosAir ...
Страница 268: ...cclxiv Jätetty tarkoituksella tyhjäksi ...
Страница 292: ...cclxxxviii Blank med hensikt ...
Страница 314: ...Intentionally left blank ...