ARITERM SWEDEN AB
•
ARITERM OY
• Asennus ja käyttöohje • Installation och driftanvisning • Installation and operating instruction • 19.11.2009 • 19/32
GUARANTEE AND DECOMMISSIONING
MOST COMMON SPARE PARTS
Guarantee
Ariterm Oy gives a two-year guarantee on the boiler starting from the date of installation. The
guarantee covers the faults related to work and raw materials that may appear in the boiler. The
manufacturer assumes no guarantee liability if the defect has been caused by an installation
fault, leaks outside the boiler, faulty operation, freezing, overheat or overpressure. If the repair
operations have been started without the manufacturer's permission or the guarantee card has
not been returned to the factory, the guarantee is not valid. The factory is not responsible for
the possible consequential damages and costs caused by the boiler. Ariterm Oy reserves the
right to decide the way in which the guarantee repair is carried out. Ariterm Oy is not liable
for damages occurred after the expiration of the guarantee period. However, compensation for
such damages may be separately agreed on a case-by-case basis.
Decommissioning
An end-of-life boiler is suitable for scrapping. Its plastic parts are landfill waste.
Product no.
Description
1163
Overheat protection EGO 55.33412.010
1774
Gasket 2x183x200, burner
5660
Grundfos UPS 25-40 pump
13245
Boiler temperature sensor
13249
Flue gas temperature sensor
13257
BeQuem 20 inner cage
13721
Display card Bm+/BQ
14048
ESBE ARA661 shunt motor
14054
Sweeping motor SPG TS09-0175
14059
Controller card B
14066
Outdoor temperature sensor
14067
Indoor temperature sensor
14067
Supply water sensor
1136
Chain wheel Z=12
13197
Hub chain wheel Z=15
13198
Hub chain wheel Z=24
1138
47-link chain
1139
Chain shackle
10667
Feed motor SPG S8I15GXCE/S8KA180M
13183
Internal casting of the burner head
13184
Internal casting of the burner head
13187
Blocking feeder
13192
Auger burner
13356
Blower SUO78613
13199
Ignition resistance 450W
10669
Level switches (incl. transmitter and receiver)
10668
Optical flame switch