ARITERM SWEDEN AB
Installation, Operation & Maintenance -
2009.02.18- 20/32
Boiler cleaning
Burning solid fuels, even if operation is automated, normally calls for a little more care
and maintenance than oil heating. For B 20/30 maintenance has been mini-
mized as the result of well planned design and a big ash box holding 50 litres.
Ash is removed when necessary. The convection parts of the boiler are to be cleaned
when the flue gas temperature has risen by 20-30˚C above the temperature of a newly
swept boiler. An alarm reminding you of cleaning can be programmed on the control
panel.
ATTENTION!
Pay special attention to the pellets quality when you receive a new delivery or when
you change supplier.
ATTENTION!
Show a great care when emptying the ash as it might be glowing hot. Ash must be
kept in a fireproof container.
The burner
Carry out checks and measures when needed or in connection with boiler cleaning
according to the following:
Normally, the burn pot does not demand any particular care, but should be
•
checked for carbon build-up in connection with ash removal. If necessary scrape
off any carbonisation.
Put the burner back into place - check carefully that no sealing is damaged.
•
Once a year to once every second year
Clean the primary ring and primary air tube on the inside to remove dust and
•
chips. Check the pins of the metering wheel, the toothed wheel and the back stop
for wear. Adjust and replace if necessary. Lubricate the driving chain with a little
thin oil.
When new pellet fuel is used, always check the burn pot for sintered ashes (crust of
ash or gravel and stone-like particles). Such particles must be removed from the burn
pot at very short intervals to prevent the primary ring from getting overheated and
damaged. Sintering is caused by impurities in the pellet fuel and a claim should be sent
to the supplier at once.
For more information please refer to ”Advice about Fuel Pellets”.
1. Switch off the burner one hour before cleaning.
2. Cleaning the convectional flues. Lift the
sweeping hatch at the top of the boiler and clean
the flues with brush. Cleaning is needed few
times a year.
3. Cleaning brush is included in Ariterm pellet
boiler delivery. Move the brush through the flues
to sweep the ash from flue walls.
4. Optional cleaning device makes the cleaning
even easier. Pull the adjuster at the top of the
boiler a few times to sweep the ash from the
flues.
MAINTENANCE, CARE, SWEEPING
Содержание Biomatic plus 50
Страница 10: ...ARITERM SWEDEN AB Installation Operation Maintenance 2009 02 18 10 32 WIRING DIAGRAM ...
Страница 25: ...ARITERM SWEDEN AB Installation Operation Maintenance 2009 02 18 25 32 FEEDING SYSTEM DEPO FEEDO 606 mm 1500 mm ...
Страница 27: ...ARITERM SWEDEN AB Installation Operation Maintenance 2009 02 18 27 32 MANUFACTURES DECLARATION ...
Страница 28: ...ARITERM SWEDEN AB Installation Operation Maintenance 2009 02 18 28 32 NOTES ...
Страница 29: ...ARITERM SWEDEN AB Installation Operation Maintenance 2009 02 18 29 32 NOTES ...
Страница 30: ...ARITERM SWEDEN AB Installation Operation Maintenance 2009 02 18 30 32 NOTES ...