ARITERM SWEDEN AB
Installation, Operation & Maintenance -
2009.02.18- 12/32
BURNER OVERVIEW
1. Primary ring
2. Primary air tube
3. Optical monitor tube
4. Level monitor, receiver
5. Top coupling
6. Level monitor, transmitter
7. Fan
8. Auger tube
9. Burn pot
10. Sluice gate
11. Auger motor (at the rear)
12. Chain
1
2
4
5
6
10
12
7
3
8
9
11
Adjusting combustion
The boiler is delivered with factory settings, which in most cases are sufficient for
proper, efficient combustion. The boiler’s factory settings can be applied if negative
pressure is 15-20 Pascal (Pa) in the flue. If combustion is poor anyway and the flue
gases from the chimney are black or the ash is grainy, combustion can be adjusted to
attain the desired end results. Adjustment is made with a flue gas analyser and should
be carried out by a service technician authorised by Ariterm. Flue gas analysis shall be
shown for carbon monoxide (CO) values under 200 ppm and excess air (O
2
) 6-8%.
The fan’s air quantity and the feed percentage for the burner screw is adjusted in the
following manner.
The amount of pellets in the burner cup is set in the output menu by changing the
percent figure for POWER HIGH AUGER and POWER LOW AUGER.
The amount of air is set in the output menu by changing the percent figure for PO-
WER HIGH FAN and POWER LOW FAN.
How electrical heating is put into service
Turn the power on in the control unit. Go to the ”SERVICE” menu by holding the
(<) and (>) buttons pressed down at the same time for approx. 5 seconds. Then
go with the (>) button to the ”ELEC STEP” menu and change the number 0 to
3 with the (+) button. Go with the (<) button to the ”FUEL” menu and select the
appropriate option (P EL) or (EL).
SETTINGS
TEMPERATURE
BOILER 55(80) °C
ON
(-OFF)
AUGER EXTERNAL
MANUAL OFF
OPERATINGMODE
MAX
TEMPERATURE
FLUE GAS xx °C
OPERATING TIME
press plus key
OPERATING TIME
TOTAL
OPERATING TIME
MAX
OPERATING TIME
MIN
OPERATING TIME
EL 1
PELLETS STORE
press plus key
SERVICE
press plus key
ESTIMATED TIME
LEFT X d
PELLETS STORE
0,0 t
FEEDING FAKTOR
0,0 kg/h
CONSUMPTION
AVERAGE 0,0 kg/d
CONSUMPTION
TOTAL 0,0 t
AUGER EXTERNAL
TOTAL XX h
ALARM PELLETS
MIN 0,0 t
ALARM ASH
REMOVE
X ( x)
ALARM
CLEANING 0( Xh)
FLUE GAS XXX °C
MAX 240°C
BURNER TYPE
30kW
POWER HIGH
AUGER 72%
POWER HIGH
FAN 45%
POWER LOW
AUGER 72%
POWER LOW
FAN 45%
POWER MIN
AUGER 0%
POWER MIN
FAN 0%
SERVICE
EL STEP
0 (0)
LEVEL MONITOR
XX (50%)
OPTICAL MONITOR
XX ( 50%)
TEST OUTPUTS
Press plus key
POWER
0
ENGLISH
ADDRESS
DEFAULT SETTINGS
v0713
DIFF TANK
NO
AUGER EXTERNAL
0
FAN
0
AUGER BURNER
0
IGNITION
0
ALARM
0
EL STEP
0
Service meny shows when
pushing same time
buttoms < and > for 5 sec.
Power menu is available
when nr. 0 is changed to
nr. 5.
Move forward when nr. on
display stops winking.
MAIN MENU
SERVICE MENU
POWER MENU
Menu is only seen when
OFF-set chosen.
FUEL
PELLETS
FUEL
P EL
FUEL
EL
Press right arrow to leave menu.
AUGER EXTERNAL
TIME MAN. 15min
HOT STARTS
BURNER X
COLD STARTS
BURNER X
SEQUENCE
Not used!
Change nr. 0 to nr. 3 when
El STEP using.
ACTIONS CHART B 30 version 0821
CLEANING
FAN 2/h
HOLDING
TIME 60min
AUGER EXTERNAL
TIME 30s
Fun must be in operation
before function of the
ignition element can be
found.
Electric heating is available
when nr 3 is selected in EL
STEP
menu.
Only B function
OPERATING TIME
EL 2
TEMPERATURE
BOILER 55(80) °C
ON
(-OFF)
AUGER EXTERNAL
MANUAL OFF
OPERATINGMODE
MAX
TEMPERATURE
FLUE GAS xx °C
OPERATING TIME
press plus key
OPERATING TIME
TOTAL
OPERATING TIME
MAX
OPERATING TIME
MIN
OPERATING TIME
EL
PELLETS STORE
press plus key
SERVICE
press plus key
ESTIMATED TIME
LEFT X d
PELLETS STORE
0,0 t
FEEDING FAKTOR
0,0 kg/h
CONSUMPTION
AVERAGE 0,0 kg/d
CONSUMPTION
TOTAL 0,0 t
AUGER EXTERNAL
TOTAL XX h
ALARM PELLETS
MIN 0,0 t
ALARM ASH
REMOVE
X ( x)
ALARM
CLEANING 0( Xh)
FLUE GAS XXX °C
MAX 240°C
BURNER TYPE
20kW
POWER HIGH
AUGER 55%
POWER HIGH
FAN 36%
POWER LOW
AUGER 55%
POWER LOW
FAN 36%
POWER MIN
AUGER 0%
POWER MIN
FAN 0%
SERVICE
EL STEP
0 (0)
LEVEL MONITOR
XX (50%)
OPTICAL MONITOR
XX ( 50%)
TEST OUTPUTS
Press plus key
POWER
0
ENGLISH
ADDRESS
DEFAULT SETTINGS
v0713
DIFF TANK
NO
AUGER EXTERNAL
0
FAN
0
AUGER BURNER
0
IGNITION
0
ALARM
0
EL STEP
0
Service meny shows when
pushing same time
buttoms < and > for 5 sec.
Power menu is available
when nr. 0 is changed to
nr. 5.
Move forward when nr. on
display stops winking.
MAIN MENU
SERVICE MENU
POWER MENU
Menu is only seen when
OFF-set chosen.
FUEL
PELLETS
FUEL
P EL
FUEL
EL
Press right arrow to leave menu.
AUGER EXTERNAL
TIME MAN. 15min
HOT STARTS
BURNER X
COLD STARTS
BURNER X
SEQUENCE
Not used!
Change nr. 0 to nr. 3 when
El STEP using.
ACTIONS CHART B 20 / BeQuem 20 version 0821
CLEANING
FAN 2/h
HOLDING
TIME 60min
AUGER EXTERNAL
TIME 30s
Fun must be in operation
before function of the
ignition element can be
found.
Electric heating is available
when nr 3 is selected in EL
STEP
menu.
Only B function
Содержание Biomatic plus 50
Страница 10: ...ARITERM SWEDEN AB Installation Operation Maintenance 2009 02 18 10 32 WIRING DIAGRAM ...
Страница 25: ...ARITERM SWEDEN AB Installation Operation Maintenance 2009 02 18 25 32 FEEDING SYSTEM DEPO FEEDO 606 mm 1500 mm ...
Страница 27: ...ARITERM SWEDEN AB Installation Operation Maintenance 2009 02 18 27 32 MANUFACTURES DECLARATION ...
Страница 28: ...ARITERM SWEDEN AB Installation Operation Maintenance 2009 02 18 28 32 NOTES ...
Страница 29: ...ARITERM SWEDEN AB Installation Operation Maintenance 2009 02 18 29 32 NOTES ...
Страница 30: ...ARITERM SWEDEN AB Installation Operation Maintenance 2009 02 18 30 32 NOTES ...