ARITERM SWEDEN AB
Installation, Operation & Maintenance -
2009.02.18- 14/32
DISPLAY MESSAGES AND POSSIBLE ADJUSTMENTS
The following tables give an overview of the messages, which may appear on the
display of the control unit. They also indicate which parameters the user is allowed to
change, and which parameters are allowed to be changed only in case that the user has
been given instructions from an authorised installer. Note that a part of the menu op-
tions are displayed only when they are activated.
Description of level 1 menu ->
Text on the display
Description
Setting possibilities
Temperature boiler xx
(80) °C
Boiler temperature, set value in brackets. Shows the
actual temperature of the boiler, the set value shows
the desired temperature.
Adjustable between 20 and 95°C by
means of the Plus and Minus buttons.
ON (OFF)
Operating mode. In ON mode the burner switches on
when needed. In OFF mode the next menu displays
“Auger external manual”.
Selectable by means of the Plus and
Minus buttons.
Operation mode, pellet
(The menu is displayed
only when the electric re-
sistors are activated)
Options:
• pellet
• electric (the function electric resistors is enabled
only in B models).
Selectable by means of the Plus and
Minus buttons.
Operation mode
OFF, start, stop, temperature hold, max, medium,
min, electric. This menu also displays the different
starting stages.
For information only.
Temperature flue gas
Flue gas temperature
For information only.
Operating time press
plus key
Press the Plus button and then the arrow button
“forward” to the next screen, if you want to view
the operating time data.
The operating time is reset by pressing
the Plus and Minus buttons simulta-
neously for 3 seconds.
Operating time total
Total operating time of the burner.
Operating time high
Operating time at high power.
Operating time low
Operating time at medium power.
Operating time min
Minimum power level during operating time (only
displayed when the min operating level is activated)
Operating time electric el1
Operating time of the resistor 1
The number of electric resistors vary bet-
ween models.
Operating time electric el2
Operating time of the resistor 2
The number of electric resistors vary bet-
ween models.
Pellet store press plus key
Press the Plus button and then the arrow button
“forward” to the next screen, if you want to view
the pellets store data.
Estimated time left
Displays the number of operating days at the avera-
ge consumption level in question.
For information only.
Text on the display
Description
Setting possibilities
Pellet store
Displays the amount of pellets in the store, a new
figure can be entered in connection with reloading
the pellets store.
For information and can be changed.
Feeding factor
Displays the feeding power of the external auger
Adjustable between 0 and 76.7 kg, see
“Determination of the feeding factor”.
Consumption average
Displays the average consumption during the last
8 days.
For information only.
Consumption total
Displays the total consumption of pellets.
For information only.
Auger external total
Displays the total operating time of the external au-
ger in hours
For information only.
Alarm pellets min
Sounds an alarm for calculated set minimum amount
of pellets in the store.
Adjustable between 0 and 3.0 tons.
Service press plus key
Press the Plus button and then the arrow button
“right” to the next screen, if you want to view the
service menu.
Alarm ash removal
Sounds an alarm for emptying the ash box upon
reaching a set value.
Adjustable between 0 and 250 h, ac-
cording to the operating time of the
external auger.
Alarm cleaning
Sounds an alarm for cleaning of the combustion
head upon reaching a set value.
Adjustable between 0 and 250 h, ac-
cording to the operating time of the
external auger.
Flue gas max °C
Audible alarm for cleaning of the convection parts
upon reaching a set value
Adjustable for alarm “max value” bet-
ween 120 and 280°C
Содержание Biomatic plus 50
Страница 10: ...ARITERM SWEDEN AB Installation Operation Maintenance 2009 02 18 10 32 WIRING DIAGRAM ...
Страница 25: ...ARITERM SWEDEN AB Installation Operation Maintenance 2009 02 18 25 32 FEEDING SYSTEM DEPO FEEDO 606 mm 1500 mm ...
Страница 27: ...ARITERM SWEDEN AB Installation Operation Maintenance 2009 02 18 27 32 MANUFACTURES DECLARATION ...
Страница 28: ...ARITERM SWEDEN AB Installation Operation Maintenance 2009 02 18 28 32 NOTES ...
Страница 29: ...ARITERM SWEDEN AB Installation Operation Maintenance 2009 02 18 29 32 NOTES ...
Страница 30: ...ARITERM SWEDEN AB Installation Operation Maintenance 2009 02 18 30 32 NOTES ...