PiCUS TreeQinetic Manual
32
3. Button: Start / Pause data recording
Switches the mode. In live mode (initial state of measurement), the measurement data
of the sensor modules are exclusively displayed live. In recording mode, the data are
permanently recorded and saved.
4. Button: Stop measurement
The measurement is stopped and all recorded data is processed for the result display.
→
the view automatically switches to the tab
Data View
and the page
Result
5. Button: Cancel measurement
The measurement is terminated and all recorded data is discarded.
→
the view automatically switches back to the tab
Project
and the page
Test Setup
5.6.2 Page
– Live View Numeric
This page displays the live data of a running measurement in a numerical way, which is also
known from the classic TreeQinetic PC software.
The data displays of the different instrument types are organized in columns. For each sensor
module found during the device search, a cell with the following information is displayed:
1. Device color (Frame)
2. Current measuring value
3. Battery status
4. Alarm status (background color of cell)
Green: No Alarm
Yellow: Measuring value is > 90% of limit value
Red: Overload alarm, measuring value has reached alarm limit
NOTE
Modules for which the alarm has been deactivated always remain in the green state.
CAUTION
In case of an interruption of the radio connection between sensors and
communication unit the last value received remains in the display of the concerned sensor.
This may look like the value was “frozen”. In fact, no current measured values are available
in this moment, so the test cannot be controlled as usual. Increasing the load without
sufficient monitoring is strongly discouraged! If the connection cannot be re-established
timely, the test must be interrupted or terminated.
1.
2.
3.
4.