5. Technical data
5.1 Device data
Nominal flow rate
45 l/min (50 Hz) or 54 l/min (60 Hz) resp.
Pressure limiting valve
6 ±0,5 bar
Max. operating pressure
7 bar
Filter element
optional
optional
optional
V7.1560-103
V7.1560-06
V7.1560-03
Y7.1560-05
β
3(c)
≥ 200
β
12(c)
≥ 200
β
5(c)
≥ 200
β
8(c)
≥ 200
(water absorption capacity ca. 1,5 liters)
NOTE
›
With use of water absorbing elements, particle counting is not possible.
›
Water in oil can adulterate the measuring results.
Clogging indicator
(all types)
optical clogging indication DG 042-04
∆
p = 3,5 ±0,5 bar
Suction side
G 1 ¼“ connection with hose DN 32 and suction pipe
(when replacing the suction hose, only use a spiral hose)
Pressure side
G 1“ connection with suction hose DN 25 and pressure pipe
Suction strainer
screen element 280 µm
Electrical drive for type
UM(P) 045-1153
UM(P) 045-1553
UM(P) 045-1656
1~ AC-motor with operating capacitor
230 V / 50 Hz; 1,1 kW; n= 1500 min
BG 90
UM(P) 045-4153
UM(P) 045-4553
UM(P) 045-4656
3~ three-phase-motor
400 / 460 V - 50 / 60 Hz; 1,1 kW; n = 1500 / 1800 min
-1
BG 90
Weight when empty
UM 45 ca. 75 kg / UMP 045 ca. 82 kg
Noise intensity level
max. 73 dB(A) under operating cond. allowed for cont. operation
max. 78 dB(A) under operating cond. allowed for short-term op
Dimensions
786 x 564 x 1045 (l x b x h)