FSHS Inc. 

23380 Janice Ave #5                                          

Port Charlotte, FL 33980                                        

                                        

PuROMax Reverse Osmosis 

Содержание PuROMax

Страница 1: ...FSHS Inc 23380 Janice Ave 5 Port Charlotte FL 33980 PuROMax Reverse Osmosis ...

Страница 2: ...ve senses when the storage tank is full and closes the water supply to conserve water The dedicated faucet is used to dispense RO produced water when needed Feed water saddle valve is connected to the cold water line to supply water to the R O system Waste water saddle valve is connected to the drain to remove reject water from the R O system Tubing supplies feed and reject water Fittings are used...

Страница 3: ...surface is required not exceeding 1 1 4 in thickness Drill the required pilot hole for the chassis punch and tighten nut to cut the desired hole size Clean up sharp edges The faucet should be positioned so it empties into the sink and the spout swivels freely for convenience If sink has a hole that can accommodate the RO faucet no drilling is required Proceed with mounting the faucet Porcelain Ena...

Страница 4: ...se with flexible ribbed supply tubing which is too thin and requires special hardware Self taping feed water saddle valve installation Installation procedures using soft copper tubing 1 Turn off cold water valve from under sink or main water line valve for whole house 2 Before installing saddle tapping valve make sure piercing lance does not protrude beyond rubber gasket 3 Assemble saddle valve on...

Страница 5: ...it installation The RO unit is normally mounted to the right or left sink cabinet sidewall depending on where supply tank is to be located Generally the unit is installed at the front of the cabinet and the tank at the rear To mount the unit elevate it at least 2 off the floor level it and mark the location of mounting holes needed Drill holes for mounting screws and install screws allowing the mo...

Страница 6: ...rrect leaks if leaks occur 3 Open valve on storage tank and open faucet until a steady stream of water flows 4 Close faucet and wait five minutes to see if leaks result Note When the system is first turned on water may intermittently spurt from the air gap opening on the side of air gap faucets This is common and should correct itself after an initial period of time Flushing system and checking op...

Страница 7: ...ove protective wrap from pre filters and membrane and install them in the appropriate filter housings Hand tighten and snug with wrench if necessary 13 Replace post carbon in line filter if necessary Note Be sure to check o rings are in place when installing cartridges in filter housings Damaged or incorrectly placed o rings will cause leaks 14 Disconnect product water tubing from the holding tank...

Страница 8: ...eneral the higher the pressure differential and temperature increased quality and quantity of water is produced These factors should be considered when sizing RO systems for a particular application PuROMax brand fittings Many RO systems utilize PuROMax brand fittings These user friendly fittings provide superior performance and may be provided with this system Proper use of these push in fittings...

Страница 9: ...PuROMaxtm 3 Stage Permeate Pump R O 3 8 Parts list available upon request ...

Страница 10: ...PuROMaxtm 4 Stage R O ...

Страница 11: ...PuROMaxtm 5 Stage R O ...

Страница 12: ...PuROMaxtm 4 Stage R O 3 8 ...

Страница 13: ...PR HN0404 1 4 Hex Nipple 2 19 PR CV0201W Automatic Shut Off Valve 1 7 FM 60 Triple Bracket 1 20 FR Flow Restrictor 1 8 C 2500W Single Clip Membrane Housing 2 21 PR MRT0604 Quick Connect 1 4 x 3 8 x 3 8 Male Run T 1 9 PR CV3142 Quick Connect 1 4 tube x 1 8 thread with check valve 1 22 TFM Membrane 1 10 DC 2500W Double Clip Membrane Housing To Inline 2 23 PE 12 BI 0500F Y 3 8 Yellow Tubing 5ft 11 MH...

Страница 14: ...manufacturer of these parts and their warranty LIMITED WARRANTY The REVERSE OSMOSIS MEMBRANE will be warrantied for a three month shelf life and a twelve month in use period for a total fifteen months Warranty begins from the date of purchase from the manufacturer Membrane is warrantied against defects when used under standard operating conditions Membranes must be kept moist at all times Defectiv...