Subject to change · UM 045_14264401
· 0916 · EN
Page 16
www.argo-hytos.com
Installing the filter element
›
Always replace the O-ring on the cover when changing the filter element (part of scope of delivery).
›
Check the type number of the filter element: Compare the numbers of the laser inscription on the filter element, the nameplate or
in the operating instructions (see page 12).
›
Attach the filter element to the cover (as shown in illustration 8).
›
Carefully insert the cover with the filter element into the filter housing.
›
Screw in the cover manually as far as the limit stop (a gap between cover and housing may remain visible.
›
Check that the ventilation slits of the electrical motor are not clogged with dirt. Remove deposits, if necessary.
›
Restart the device.
›
Check the tightness of the filter housing after starting operation.
Illustration 8:
Attaching the cover to the element
NOTE
›
Oil which accidently spilt onto the filter unit when changing the filter element may seem to be leaked oil.
8.3 Checking / changing of the suction strainer (protective strainer for the pump)
When changing the suction strainer please proceed as follows (also see illustration 7 and illustration 8):
Replacing the suction strainer
›
Provide a drip tray for residual oil and the clogged filter element.
›
Unscrew the locking screw (item 1) by hexagon socket screw key SW 22.
›
Slightly pull the clogged element out of the housing.
›
Dispose of the filter element in line with environmental requirements, waste code: OILFILTER 16 01 07
1
Illustration 9:
Unscrewing the locking screw