Mode
Description
Values
Special Effects Settings
“--:--:09”
flashing
Use LDR
. If you disable the LDR, the tubes will always work at
maximum brightness.
“1” = enable
“0” = disable
default: 1
“--:--:10”
flashing
Blank Mode.
You can set the tubes, the LEDs or both the tubes
and the LEDs to be blanked when in blanking mode.
“0” = tubes
“1” = LEDs
“2” = tubes and LEDs
default: 2
“--:--:11”
flashing
Fade Speed Slower
. Each short press will make the fade speed
between digits slower.
Default: 50
Max: 200
Min: 20
“--:--:12”
flashing
Fade Speed Faster
. Each short press will make the fade speed
between digits faster.
Default: 50
Max: 200
Min: 20
“--:--:13”
flashing
Scroll-back Speed Slower.
Each short press will make the
“scroll-back” speed slower.
Default: 4
Max: 40
Min: 1
“--:--:14”
flashing
Scroll-back Speed Faster.
Each short press will make the
“scroll-back” speed faster.
Default: 4
Max: 40
Min: 1
“--:--:15”
flashing
Slots Mode.
You can have the date shown automatically once per
minute for about 5 seconds.
“1” = enable
“0” = disable
default: 1
Back Light Settings
“--:--:16”
flashing
Back Light Mode.
This sets the mode of the back light.
“Fixed” mode will show the back light color according to the Red,
Green and Blue channel intensities.
“Pulse” will make the intensity of the back light “pulse”, brightening
for a second and then darkening for a second, but always respecting
the relative intensities set by the Red, Green and Blue channel
intensities.
“Cycle” fades the back lighting randomly, and does not use the Red,
Green and Blue channel intensities. These settings will be skipped if
cycle mode is selected.
Options “0”, “1” and “2”, do not dim with the bulbs. Options “3”, “4”
and “5” do.
“0” = Fixed
“1” = Pulse
“2” = Cycle
“3” = Fixed/Dim
“4” = Pulse/Dim
“5” = Cycle/Dim
default: 0
“--:--:17”
flashing
Red Channel Intensity.
Sets the maximum intensity of the red
channel back light. This will be dimmed according to the display
dimming. If you are in cycle mode, this setting will be skipped.
Default: 15
Max: 15
Min: 0
“--:--:18”
flashing
Green Channel Intensity.
Sets the maximum intensity of the
green channel back light. This will be dimmed according to the
display dimming. If you are in cycle mode, this setting will be
skipped.
Default: 15
Max: 15
Min: 0
“--:--:19”
flashing
Blue Channel Intensity.
Sets the maximum intensity of the blue
channel back light. This will be dimmed according to the display
dimming. If you are in cycle mode, this setting will be skipped.
Default: 15
Max: 15
Min: 0
Содержание All-In-One