Safety

The voltages produced in the High Voltage circuit can reach peaks of 400V! Take precautions not to 
electrocute yourself! If you are not sure what this means, please do not use this clock and return it for a full 
refund.

A shock from the clock high voltage circuit is at least a nasty bite. At worst it can kill you.

We decline any responsibility in the case of injury or death. You must be qualified to use this clock, it is not 
intended for anyone unqualified.

REPEAT: If you are not sure what this means, do not use the clock!

General

The clock has different modes of operation, which you select using the pushbutton.

First Start and calibration

When you start the clock up th very first time, it will start in “First Start Mode”. This mode is intended to 
simplify the set up of the hardware. It cycles through the digits “0” - “9” and drives the High Voltage 
Generator with a basic setting which does no dimming.

To 

EXIT First Start Mode, press the pushbutton when the display shows “88:88:88”, and 

the clock will enter calibration mode!

The clock will display 

“88:88:88”

 for several seconds. This is for the calibration of the High Voltage 

Generator to match the power adapter you have attached. During this time you might hear some faint 
crackling noises from the generator. This is normal.
After finishing the calibration, the version number (

“00:47:07”

) will be displayed for about a second. The 

clock will then go into normal operating mode.

You will use this function when you are building the High Voltage circuit.

For a video of the startup process, please see:

https://youtu.be/XA3LOPLX8vI

Once you have exited First Start Mode, it will not enter it again until you do a factory reset (See below).

Clock Mode

After the first start, each time you start up the unit, the clock will go into normal clock mode and will display 
the time. In normal clock mode, the time will be displayed.

Every 10 minutes (at 

“xx:x9:15”

, the clock will do “Anti-Cathode Poisoning”, which will cycle all the digits for 

about 15 seconds.

This is not an error! It is important to keep the tubes healthy in the long term.

Содержание All-In-One

Страница 1: ...Arduino Nixie Clock Classic Rev4 and Rev5 All In One Operating Instructions Firmware V52 Supported Models Classic Rev4 Classic Rev5 All In One...

Страница 2: ...NixieClockUserManualV52...

Страница 3: ...mail ch We ll usually get back to you right away We can help you with kits or construction We also offer discounts for direct purchases we save the Ebay fees and share this with you http www open rate...

Страница 4: ...in a bedroom Automatic week day or weekend blanking extends the life of tubes even further Automatic time of day blanking can blank between a start hour and an end hour on week days weekends or every...

Страница 5: ...ress the pushbutton when the display shows 88 88 88 and the clock will enter calibration mode The clock will display 88 88 88 for several seconds This is for the calibration of the High Voltage Genera...

Страница 6: ...er Additionally the WiFi time module gives you a easy to configure interface which you can use to set up the clock using a tablet phone or computer Overview Normally the clock is in Time Display Mode...

Страница 7: ...xample 22 25 13 Means 22 25 Degrees WiFi and RTC installed LDR Ambient Light Reading This shows the current ambient light reading from the LDR light dependent resistor It is a normalized value and goe...

Страница 8: ...up mode of the clock If you do nothing The clock is in this mode In this mode a short press cycles through the values given in Time Display Mode but always returns to the standard time display after...

Страница 9: ...very other day 6 Hours or week days This blanks all day during the week days and between the start and end hour every other day 7 Hours on weekends This blanks between the start and end hour on weeken...

Страница 10: ...back light color according to the Red Green and Blue channel intensities Pulse will make the intensity of the back light pulse brightening for a second and then darkening for a second but always resp...

Страница 11: ...ncrease the minimum brightness you want to have when the clock is fully dimmed Default 100 Max 500 Min 100 26 flashing Decrease Minimum dim This setting allows you to decrease the minimum brightness y...

Страница 12: ...tton more than 8 seconds the clock will enter filament healing mode All the power will be placed through a single filament of a single digit to clean it A short press will change the selected filament...

Страница 13: ...Revisions V0047 22Jun2017 Split user manual and construction manual V0048 16Jul2017 Update for V48 V0051 24May2018 Update for V51 V0052 15Jun2018 Update for V52 new Nixie font...

Отзывы: