Display Blanking Mode

During display blanking mode the tubes will be off depending on the display blanking settings, but the LEDs 
will continue to work as usual, telling you that the clock is still running.

You can configure the display to blank at weekends, during week days, always or never (the default). Also 
you are able to define hours during which to blank. For example I have a setting saying that the clock is 
blanked on weekdays between 7am and 4 pm, while I am out at work. At weekends, the display runs all the 
time.

You are also able to override the blanking. Press the button while the clock is blanked, and the display will 
come on again. Pressing the button will display the time for about a minute (60 seconds, but the display is 
only blanked on the minute change).

If you press the button multiple times within 5 seconds, the blanking will stay off for longer periods:

1 Press: 10 seconds

2 Presses: 1 hour

3 Presses: 4 hours

Tube Healing Mode

After a long period of time, tube filaments which are not often used (e.g. the “9” on the tens of hours or 
minutes) can get dim, despite the ACP that is regularly done.

If you make a “long” press of the button (more than 8 seconds), the clock will enter filament healing mode. All
the power will be placed through a single filament of a single digit to clean it. A short press will change the 
selected filament.

Another super-long press or cycling through all the filaments will return the clock to normal.

Caution!

 Don't leave a single filament in this state for an extended period of time. It is a harsh process, and

may damage the tube if you leave it in this mode for too long. Normally a few seconds minutes will restore 
the cathode digit.

Normally you will not need to use this mode! It is only there for tubes that are already in trouble. 

Don’t 

make a habit of using this mode!

Factory Reset

To reset the clock back to initial settings, hold down the button while powering on. The LEDs will rapidly flash
some colours to signal that the reset has been done.

Everything will be reset back to the factory default state, and the clock will go back to “First Start Mode”.

External power supply

The perfect voltage for the external power supply is 7.5V or 9V DC. You can use 12V DC.

If you use more than 12V be aware that you might have to provide a heat sink for the power components and
adjust the HV voltage generation. It is not advised to use more than 12V.

The absolute maximum permissible is 16V DC. Higher voltages than this will surely damage the clock.

Содержание All-In-One

Страница 1: ...Arduino Nixie Clock Classic Rev4 and Rev5 All In One Operating Instructions Firmware V52 Supported Models Classic Rev4 Classic Rev5 All In One...

Страница 2: ...NixieClockUserManualV52...

Страница 3: ...mail ch We ll usually get back to you right away We can help you with kits or construction We also offer discounts for direct purchases we save the Ebay fees and share this with you http www open rate...

Страница 4: ...in a bedroom Automatic week day or weekend blanking extends the life of tubes even further Automatic time of day blanking can blank between a start hour and an end hour on week days weekends or every...

Страница 5: ...ress the pushbutton when the display shows 88 88 88 and the clock will enter calibration mode The clock will display 88 88 88 for several seconds This is for the calibration of the High Voltage Genera...

Страница 6: ...er Additionally the WiFi time module gives you a easy to configure interface which you can use to set up the clock using a tablet phone or computer Overview Normally the clock is in Time Display Mode...

Страница 7: ...xample 22 25 13 Means 22 25 Degrees WiFi and RTC installed LDR Ambient Light Reading This shows the current ambient light reading from the LDR light dependent resistor It is a normalized value and goe...

Страница 8: ...up mode of the clock If you do nothing The clock is in this mode In this mode a short press cycles through the values given in Time Display Mode but always returns to the standard time display after...

Страница 9: ...very other day 6 Hours or week days This blanks all day during the week days and between the start and end hour every other day 7 Hours on weekends This blanks between the start and end hour on weeken...

Страница 10: ...back light color according to the Red Green and Blue channel intensities Pulse will make the intensity of the back light pulse brightening for a second and then darkening for a second but always resp...

Страница 11: ...ncrease the minimum brightness you want to have when the clock is fully dimmed Default 100 Max 500 Min 100 26 flashing Decrease Minimum dim This setting allows you to decrease the minimum brightness y...

Страница 12: ...tton more than 8 seconds the clock will enter filament healing mode All the power will be placed through a single filament of a single digit to clean it A short press will change the selected filament...

Страница 13: ...Revisions V0047 22Jun2017 Split user manual and construction manual V0048 16Jul2017 Update for V48 V0051 24May2018 Update for V51 V0052 15Jun2018 Update for V52 new Nixie font...

Отзывы: